1.8 KiB
1.8 KiB
1 | Unit | Values | Description | |
---|---|---|---|---|
2 | cutout | -- | Should be a folder listed in the configuration ``atlite: cutouts:`` (e.g. 'europe-2013-era5') or reference an existing folder in the directory ``cutouts``. Source module must be ERA5. | Specifies the directory where the relevant weather data ist stored. |
3 | resource | |||
4 | -- method | -- | Must be 'wind' | A superordinate technology type. |
5 | -- turbine | -- | One of turbine types included in `atlite <https://github.com/PyPSA/atlite/tree/master/atlite/resources/windturbine>`_ | Specifies the turbine type and its characteristic power curve. |
6 | capacity_per_sqkm | :math:`MW/km^2` | float | Allowable density of wind turbine placement. |
7 | corine | -- | Any *realistic* subset of the `CORINE Land Cover code list <http://www.eea.europa.eu/data-and-maps/data/corine-land-cover-2006-raster-1/corine-land-cover-classes-and/clc_legend.csv/at_download/file>`_ | Specifies areas according to CORINE Land Cover codes which are generally eligible for AC-connected offshore wind turbine placement. |
8 | natura | bool | {true, false} | Switch to exclude `Natura 2000 <https://en.wikipedia.org/wiki/Natura_2000>`_ natural protection areas. Area is excluded if ``true``. |
9 | max_depth | m | float | Maximum sea water depth at which wind turbines can be build. Maritime areas with deeper waters are excluded in the process of calculating the AC-connected offshore wind potential. |
10 | min_shore_distance | m | float | Minimum distance to the shore below which wind turbines cannot be build. Such areas close to the shore are excluded in the process of calculating the AC-connected offshore wind potential. |
11 | potential | -- | One of {'simple', 'conservative'} | Method to compute the maximal installable potential for a node; confer :ref:`renewableprofiles` |
12 | clip_p_max_pu | p.u. | float | To avoid too small values in the renewables` per-unit availability time series values below this threshold are set to zero. |