1UnitValuesDescription
2voltageskVAny subset of {220., 300., 380.}Voltage levels to consider
3gaslimit_enablebooltrue or falseAdd an overall absolute gas limit configured in ``electricity: gaslimit``.
4gaslimitMWhthfloat or falseGlobal gas usage limit
5co2limit:math:`t_{CO_2-eq}/a`floatCap on total annual system carbon dioxide emissions
6co2base:math:`t_{CO_2-eq}/a`floatReference value of total annual system carbon dioxide emissions if relative emission reduction target is specified in ``{opts}`` wildcard.
7agg_p_nom_limitsfilepathReference to ``.csv`` file specifying per carrier generator nominal capacity constraints for individual countries if ``'CCL'`` is in ``{opts}`` wildcard. Defaults to ``data/agg_p_nom_minmax.csv``.
8operational_reserveSettings for reserve requirements following `GenX <https://genxproject.github.io/GenX/dev/core/#Reserves>`_
9
10-- activatebooltrue or falseWhether to take operational reserve requirements into account during optimisation
11-- epsilon_load--floatshare of total load
12-- epsilon_vres--floatshare of total renewable supply
13-- contingencyMWfloatfixed reserve capacity
14max_hours
15-- batteryhfloatMaximum state of charge capacity of the battery in terms of hours at full output capacity ``p_nom``. Cf. `PyPSA documentation <https://pypsa.readthedocs.io/en/latest/components.html#storage-unit>`_.
16-- H2hfloatMaximum state of charge capacity of the hydrogen storage in terms of hours at full output capacity ``p_nom``. Cf. `PyPSA documentation <https://pypsa.readthedocs.io/en/latest/components.html#storage-unit>`_.
17extendable_carriers
18-- Generator--Any extendable carrierDefines existing or non-existing conventional and renewable power plants to be extendable during the optimization. Conventional generators can only be built/expanded where already existent today. If a listed conventional carrier is not included in the ``conventional_carriers`` list, the lower limit of the capacity expansion is set to 0.
19-- StorageUnit--Any subset of {'battery','H2'}Adds extendable storage units (battery and/or hydrogen) at every node/bus after clustering without capacity limits and with zero initial capacity.
20-- Store--Any subset of {'battery','H2'}Adds extendable storage units (battery and/or hydrogen) at every node/bus after clustering without capacity limits and with zero initial capacity.
21-- Link--Any subset of {'H2 pipeline'}Adds extendable links (H2 pipelines only) at every connection where there are lines or HVDC links without capacity limits and with zero initial capacity. Hydrogen pipelines require hydrogen storage to be modelled as ``Store``.
22powerplants_filter--use `pandas.query <https://pandas.pydata.org/pandas-docs/stable/reference/api/pandas.DataFrame.query.html>`_ strings here, e.g. ``Country not in ['Germany']``Filter query for the default powerplant database.
23
24custom_powerplants--use `pandas.query <https://pandas.pydata.org/pandas-docs/stable/reference/api/pandas.DataFrame.query.html>`_ strings here, e.g. ``Country in ['Germany']``Filter query for the custom powerplant database.
25
26everywhere_powerplants--Any subset of {nuclear, oil, OCGT, CCGT, coal, lignite, geothermal, biomass}List of conventional power plants to add to every node in the model with zero initial capacity. To be used in combination with ``extendable_carriers`` to allow for building conventional powerplants irrespective of existing locations.
27
28conventional_carriers--Any subset of {nuclear, oil, OCGT, CCGT, coal, lignite, geothermal, biomass}List of conventional power plants to include in the model from ``resources/powerplants.csv``. If an included carrier is also listed in ``extendable_carriers``, the capacity is taken as a lower bound.
29
30renewable_carriers--Any subset of {solar, onwind, offwind-ac, offwind-dc, offwind-float, hydro}List of renewable generators to include in the model.
31estimate_renewable_capacities
32-- enableboolActivate routine to estimate renewable capacities
33-- from_opsd--boolAdd renewable capacities from `OPSD database <https://data.open-power-system-data.org/renewable_power_plants/2020-08-25>`_. The value is depreciated but still can be used.
34-- year--boolRenewable capacities are based on existing capacities reported by IRENA (IRENASTAT) for the specified year
35-- expansion_limit--float or falseArtificially limit maximum IRENA capacities to a factor. For example, an ``expansion_limit: 1.1`` means 110% of capacities . If false are chosen, the estimated renewable potentials determine by the workflow are used.
36-- technology_mappingMapping between PyPSA-Eur and powerplantmatching technology names
37-- -- Offshore--Any subset of {offwind-ac, offwind-dc, offwind-float}List of PyPSA-Eur carriers that is considered as (IRENA, OPSD) onshore technology.
38-- -- Offshore--{onwind}List of PyPSA-Eur carriers that is considered as (IRENA, OPSD) offshore technology.
39-- -- PV--{solar}List of PyPSA-Eur carriers that is considered as (IRENA, OPSD) PV technology.
40autarky
41-- enablebooltrue or falseRequire each node to be autarkic by removing all lines and links.
42-- by_countrybooltrue or falseRequire each country to be autarkic by removing all cross-border lines and links. ``electricity: autarky`` must be enabled.