pypsa-eur/doc/configtables/lines.csv
Fabian Neumann 6deac6ced3 merge master
2020-10-03 11:15:39 +02:00

977 B

1UnitValuesDescription
2types--Values should specify a `line type in PyPSA <https://pypsa.readthedocs.io/en/latest/components.html#line-types>`_. Keys should specify the corresponding voltage level (e.g. 220., 300. and 380. kV)Specifies line types to assume for the different voltage levels of the ENTSO-E grid extraction. Should normally handle voltage levels 220, 300, and 380 kV
3s_max_pu--Value in [0.,1.]Correction factor for line capacities (``s_nom``) to approximate :math:`N-1` security and reserve capacity for reactive power flows
4s_nom_maxMWfloatGlobal upper limit for the maximum capacity of each extendable line.
5length_factor--floatCorrection factor to account for the fact that buses are *not* connected by lines through air-line distance.
6under_construction--One of {'zero': set capacity to zero, 'remove': remove completely, 'keep': keep with full capacity}Specifies how to handle lines which are currently under construction.