pypsa-eur/data/costs.csv
Tom Brown 49a68bdd35 Separate CHP gas/solid biomass, with/without CCS
Also fix CHP p_nom_ratio constraint, and battery charger/discharger
constraint.
2019-12-12 15:03:51 +01:00

16 KiB

1technologyyearparametervalueunitsource
2solar-rooftop2030discount rate0.04per unitstandard for decentral
3onwind2030lifetime25yearsIEA2010
4offwind2030lifetime25yearsIEA2010
5solar2030lifetime25yearsIEA2010
6solar-rooftop2030lifetime25yearsIEA2010
7solar-utility2030lifetime25yearsIEA2010
8PHS2030lifetime80yearsIEA2010
9hydro2030lifetime80yearsIEA2010
10ror2030lifetime80yearsIEA2010
11OCGT2030lifetime30yearsIEA2010
12nuclear2030lifetime45yearsECF2010 in DIW DataDoc http://hdl.handle.net/10419/80348
13CCGT2030lifetime30yearsIEA2010
14coal2030lifetime40yearsIEA2010
15lignite2030lifetime40yearsIEA2010
16geothermal2030lifetime40yearsIEA2010
17biomass2030lifetime30yearsECF2010 in DIW DataDoc http://hdl.handle.net/10419/80348
18oil2030lifetime30yearsECF2010 in DIW DataDoc http://hdl.handle.net/10419/80348
19onwind2030investment1182EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
20offwind2030investment2506EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
21solar2030investment600EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
22biomass2030investment2209EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
23geothermal2030investment3392EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
24coal2030investment1300EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348 PC (Advanced/SuperC)
25lignite2030investment1500EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
26solar-rooftop2030investment725EUR/kWelETIP PV
27solar-utility2030investment425EUR/kWelETIP PV
28PHS2030investment2000EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
29hydro2030investment2000EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
30ror2030investment3000EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
31OCGT2030investment400EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
32nuclear2030investment6000EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
33CCGT2030investment800EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
34oil2030investment400EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
35onwind2030FOM2.961083%/yearDIW DataDoc http://hdl.handle.net/10419/80348
36offwind2030FOM3.192338%/yearDIW DataDoc http://hdl.handle.net/10419/80348
37solar2030FOM4.166667%/yearDIW DataDoc http://hdl.handle.net/10419/80348
38solar-rooftop2030FOM2%/yearETIP PV
39solar-utility2030FOM3%/yearETIP PV
40biomass2030FOM4.526935%/yearDIW DataDoc http://hdl.handle.net/10419/80348
41geothermal2030FOM2.358491%/yearDIW DataDoc http://hdl.handle.net/10419/80348
42coal2030FOM1.923076%/yearDIW DataDoc http://hdl.handle.net/10419/80348 PC (Advanced/SuperC)
43lignite2030FOM2.0%/yearDIW DataDoc http://hdl.handle.net/10419/80348 PC (Advanced/SuperC)
44oil2030FOM1.5%/yearDIW DataDoc http://hdl.handle.net/10419/80348
45PHS2030FOM1%/yearDIW DataDoc http://hdl.handle.net/10419/80348
46hydro2030FOM1%/yearDIW DataDoc http://hdl.handle.net/10419/80348
47ror2030FOM2%/yearDIW DataDoc http://hdl.handle.net/10419/80348
48CCGT2030FOM2.5%/yearDIW DataDoc http://hdl.handle.net/10419/80348
49OCGT2030FOM3.75%/yearDIW DataDoc http://hdl.handle.net/10419/80348
50onwind2030VOM0.015EUR/MWhelRES costs made up to fix curtailment order
51offwind2030VOM0.02EUR/MWhelRES costs made up to fix curtailment order
52solar2030VOM0.01EUR/MWhelRES costs made up to fix curtailment order
53coal2030VOM6EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348 PC (Advanced/SuperC)
54lignite2030VOM7EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348
55CCGT2030VOM4EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348
56OCGT2030VOM3EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348
57nuclear2030VOM8EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348
58gas2030fuel21.6EUR/MWhthIEA2011b
59uranium2030fuel3EUR/MWhthDIW DataDoc http://hdl.handle.net/10419/80348
60oil2030VOM3EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348
61nuclear2030fuel3EUR/MWhthIEA2011b
62biomass2030fuel7EUR/MWhthIEA2011b
63coal2030fuel8.4EUR/MWhthIEA2011b
64lignite2030fuel2.9EUR/MWhthIEA2011b
65biogas2030fuel59EUR/MWhthJRC and Zappa
66solid biomass2030fuel25.2EUR/MWhthJRC and Zappa
67oil2030fuel50EUR/MWhthIEA WEM2017 97USD/boe = http://www.iea.org/media/weowebsite/2017/WEM_Documentation_WEO2017.pdf
68PHS2030efficiency0.75per unitDIW DataDoc http://hdl.handle.net/10419/80348
69hydro2030efficiency0.9per unitDIW DataDoc http://hdl.handle.net/10419/80348
70ror2030efficiency0.9per unitDIW DataDoc http://hdl.handle.net/10419/80348
71OCGT2030efficiency0.39per unitDIW DataDoc http://hdl.handle.net/10419/80348
72CCGT2030efficiency0.5per unitDIW DataDoc http://hdl.handle.net/10419/80348
73biomass2030efficiency0.468per unitDIW DataDoc http://hdl.handle.net/10419/80348
74geothermal2030efficiency0.239per unitDIW DataDoc http://hdl.handle.net/10419/80348
75nuclear2030efficiency0.337per unitDIW DataDoc http://hdl.handle.net/10419/80348
76gas2030CO2 intensity0.187tCO2/MWthhttps://www.eia.gov/environment/emissions/co2_vol_mass.php
77coal2030efficiency0.464per unitDIW DataDoc http://hdl.handle.net/10419/80348 PC (Advanced/SuperC)
78lignite2030efficiency0.447per unitDIW DataDoc http://hdl.handle.net/10419/80348
79oil2030efficiency0.393per unitDIW DataDoc http://hdl.handle.net/10419/80348 CT
80coal2030CO2 intensity0.354tCO2/MWthhttps://www.eia.gov/environment/emissions/co2_vol_mass.php
81lignite2030CO2 intensity0.4tCO2/MWthGerman sources
82oil2030CO2 intensity0.248tCO2/MWthhttps://www.eia.gov/environment/emissions/co2_vol_mass.php
83geothermal2030CO2 intensity0.026tCO2/MWthhttps://www.eia.gov/environment/emissions/co2_vol_mass.php
84solid biomass2030CO2 intensity0.3tCO2/MWthTODO
85electrolysis2030investment350EUR/kWelPalzer Thesis
86electrolysis2030FOM4%/yearNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
87electrolysis2030lifetime18yearsNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
88electrolysis2030efficiency0.8per unitNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
89fuel cell2030investment339EUR/kWelNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
90fuel cell2030FOM3%/yearNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
91fuel cell2030lifetime20yearsNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
92fuel cell2030efficiency0.58per unitNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013 conservative 2020
93hydrogen storage2030investment11.2USD/kWhbudischak2013
94hydrogen storage2030lifetime20yearsbudischak2013
95hydrogen underground storage2030investment0.5EUR/kWhmaximum from https://www.nrel.gov/docs/fy10osti/46719.pdf
96hydrogen underground storage2030lifetime40yearshttp://www.acatech.de/fileadmin/user_upload/Baumstruktur_nach_Website/Acatech/root/de/Publikationen/Materialien/ESYS_Technologiesteckbrief_Energiespeicher.pdf
97H2 pipeline2030investment267EUR/MW/kmWelder et al https://doi.org/10.1016/j.ijhydene.2018.12.156
98H2 pipeline2030lifetime40yearsTODO
99H2 pipeline2030FOM3%/yearTODO
100methanation2030investment1000EUR/kWH2Schaber thesis
101methanation2030lifetime25yearsSchaber thesis
102methanation2030FOM3%/yearSchaber thesis
103methanation2030efficiency0.8per unitPalzer and Schaber thesis
104helmeth2030investment2000EUR/kWno source
105helmeth2030lifetime25yearsno source
106helmeth2030FOM3%/yearno source
107helmeth2030efficiency0.8per unitHELMETH press release
108SMR2030investment540.56EUR/kWCH4https://www.gov.uk/government/publications/hydrogen-supply-chain-evidence-base; slide 42 assumption for 2030; GBP 466 exchange 1.16
109SMR2030lifetime25yearsTODO
110SMR2030FOM5.4%/yearhttps://www.gov.uk/government/publications/hydrogen-supply-chain-evidence-base; slide 42 assumption for 2030
111SMR2030efficiency0.74per unithttps://www.gov.uk/government/publications/hydrogen-supply-chain-evidence-base; slide 42 assumption for 2030
112Fischer-Tropsch2030investment677.6EUR/kWH2Fasihi doi:10.3390/su9020306 (60 kEUR/bpd = 847 EUR/kWL (1b = 1.7 MWh) 847*0.8 = 677.6)
113Fischer-Tropsch2030lifetime30yearsdoi:10.3390/su9020306
114Fischer-Tropsch2030FOM3%/yeardoi:10.3390/su9020306
115Fischer-Tropsch2030efficiency0.8per unitTODO
116DAC2030investment250EUR/(tCO2/a)Fasihi doi:10.3390/su9020306/Climeworks
117DAC2030lifetime30yearsFasihi
118DAC2030FOM4%/yearFasihi
119battery inverter2030investment411USD/kWelbudischak2013
120battery inverter2030lifetime20yearsbudischak2013
121battery inverter2030efficiency0.81per unitbudischak2013; Lund and Kempton (2008) http://dx.doi.org/10.1016/j.enpol.2008.06.007
122battery inverter2030FOM3%/yearbudischak2013
123battery storage2030investment192USD/kWhbudischak2013
124battery storage2030lifetime15yearsbudischak2013
125decentral air-sourced heat pump2030investment1050EUR/kWthHP; Palzer thesis
126decentral air-sourced heat pump2030lifetime20yearsHP; Palzer thesis
127decentral air-sourced heat pump2030FOM3.5%/yearPalzer thesis
128decentral air-sourced heat pump2030efficiency3per unitdefault for costs
129decentral air-sourced heat pump2030discount rate0.04per unitPalzer thesis
130decentral ground-sourced heat pump2030investment1400EUR/kWthPalzer thesis
131decentral ground-sourced heat pump2030lifetime20yearsPalzer thesis
132decentral ground-sourced heat pump2030FOM3.5%/yearPalzer thesis
133decentral ground-sourced heat pump2030efficiency4per unitdefault for costs
134decentral ground-sourced heat pump2030discount rate0.04per unitPalzer thesis
135central air-sourced heat pump2030investment700EUR/kWthPalzer thesis
136central air-sourced heat pump2030lifetime20yearsPalzer thesis
137central air-sourced heat pump2030FOM3.5%/yearPalzer thesis
138central air-sourced heat pump2030efficiency3per unitdefault for costs
139retrofitting I2030discount rate0.04per unitPalzer thesis
140retrofitting I2030lifetime50yearsPalzer thesis
141retrofitting I2030FOM1%/yearPalzer thesis
142retrofitting I2030investment50EUR/m2/fraction reductionPalzer thesis
143retrofitting II2030discount rate0.04per unitPalzer thesis
144retrofitting II2030lifetime50yearsPalzer thesis
145retrofitting II2030FOM1%/yearPalzer thesis
146retrofitting II2030investment250EUR/m2/fraction reductionPalzer thesis
147water tank charger2030efficiency0.9per unitHP
148water tank discharger2030efficiency0.9per unitHP
149decentral water tank storage2030investment860EUR/m3IWES Interaktion
150decentral water tank storage2030FOM1%/yearHP
151decentral water tank storage2030lifetime20yearsHP
152decentral water tank storage2030discount rate0.04per unitPalzer thesis
153central water tank storage2030investment30EUR/m3IWES Interaktion
154central water tank storage2030FOM1%/yearHP
155central water tank storage2030lifetime40yearsHP
156decentral resistive heater2030investment100EUR/kWhthSchaber thesis
157decentral resistive heater2030lifetime20yearsSchaber thesis
158decentral resistive heater2030FOM2%/yearSchaber thesis
159decentral resistive heater2030efficiency0.9per unitSchaber thesis
160decentral resistive heater2030discount rate0.04per unitPalzer thesis
161central resistive heater2030investment100EUR/kWhthSchaber thesis
162central resistive heater2030lifetime20yearsSchaber thesis
163central resistive heater2030FOM2%/yearSchaber thesis
164central resistive heater2030efficiency0.9per unitSchaber thesis
165decentral gas boiler2030investment175EUR/kWhthPalzer thesis
166decentral gas boiler2030lifetime20yearsPalzer thesis
167decentral gas boiler2030FOM2%/yearPalzer thesis
168decentral gas boiler2030efficiency0.9per unitPalzer thesis
169decentral gas boiler2030discount rate0.04per unitPalzer thesis
170central gas boiler2030investment63EUR/kWhthPalzer thesis
171central gas boiler2030lifetime22yearsPalzer thesis
172central gas boiler2030FOM1%/yearPalzer thesis
173central gas boiler2030efficiency0.9per unitPalzer thesis
174decentral CHP2030lifetime25yearsHP
175decentral CHP2030investment1400EUR/kWelHP
176decentral CHP2030FOM3%/yearHP
177decentral CHP2030discount rate0.04per unitPalzer thesis
178central gas CHP2030lifetime30yearsDEA
179central gas CHP2030investment1300EUR/kWelDEA
180central gas CHP2030FOM3%/yearDEA
181central gas CHP2030efficiency0.45per unitDEA (condensation mode)
182central gas CHP2030c_b0.7per unitDEA (backpressure ratio)
183central gas CHP2030c_v0.17per unitDEA (loss of fuel for additional heat)
184central gas CHP2030p_nom_ratio1.per unit
185central gas CHP2030VOM0.82EUR/MWhDEA
186central gas CHP CCS2030lifetime30yearsDEA
187central gas CHP CCS2030investment1900EUR/kWelDEA + DIW extra for CCS on gas plant
188central gas CHP CCS2030FOM3%/yearDEA
189central gas CHP CCS2030efficiency0.405per unitDEA (condensation mode + efficiency loss due to capture)
190central gas CHP CCS2030c_b0.7per unitDEA (backpressure ratio)
191central gas CHP CCS2030c_v0.17per unitDEA (loss of fuel for additional heat)
192central gas CHP CCS2030p_nom_ratio1.per unit
193central gas CHP CCS2030VOM0.82EUR/MWhDEA
194central solid biomass CHP2030lifetime40yearsDEA
195central solid biomass CHP2030investment1990EUR/kWelDEA
196central solid biomass CHP2030FOM3%/yearDEA
197central solid biomass CHP2030efficiency0.52per unitDEA (condensation mode)
198central solid biomass CHP2030c_b1.01per unitDEA (backpressure ratio)
199central solid biomass CHP2030c_v0.15per unitDEA (loss of fuel for additional heat)
200central solid biomass CHP2030p_nom_ratio1.per unit
201central solid biomass CHP2030VOM2.2EUR/MWhDEA
202central solid biomass CHP CCS2030lifetime40yearsDEA
203central solid biomass CHP CCS2030investment2590EUR/kWelDEA + DIW extra for CCS on gas plant
204central solid biomass CHP CCS2030FOM3%/yearDEA
205central solid biomass CHP CCS2030efficiency0.468per unitDEA (condensation mode + efficiency loss due to capture)
206central solid biomass CHP CCS2030c_b1.01per unitDEA (backpressure ratio)
207central solid biomass CHP CCS2030c_v0.15per unitDEA (loss of fuel for additional heat)
208central solid biomass CHP CCS2030p_nom_ratio1.per unit
209central solid biomass CHP CCS2030VOM2.2EUR/MWhDEA
210micro CHP2030lifetime20yearsDEA for PEMFC with methane (for unit consuming 2kW CH4)
211micro CHP2030investment4500EUR/kWCH4DEA for PEMFC with methane (for unit consuming 2kW CH4)
212micro CHP2030FOM6%/yearDEA for PEMFC with methane (for unit consuming 2kW CH4)
213micro CHP2030efficiency0.351per unitDEA for PEMFC with methane (for unit consuming 2kW CH4)
214micro CHP2030efficiency-heat0.609per unitDEA for PEMFC with methane (for unit consuming 2kW CH4)
215decentral solar thermal2030discount rate0.04per unitPalzer thesis
216decentral solar thermal2030FOM1.3%/yearHP
217decentral solar thermal2030investment270000EUR/1000m2HP
218decentral solar thermal2030lifetime20yearsHP
219central solar thermal2030FOM1.4%/yearHP
220central solar thermal2030investment140000EUR/1000m2HP
221central solar thermal2030lifetime20yearsHP
222HVAC overhead2030investment400EUR/MW/kmHagspiel
223HVAC overhead2030lifetime40yearsHagspiel
224HVAC overhead2030FOM2%/yearHagspiel
225HVDC overhead2030investment400EUR/MW/kmHagspiel
226HVDC overhead2030lifetime40yearsHagspiel
227HVDC overhead2030FOM2%/yearHagspiel
228HVDC submarine2030investment2000EUR/MW/kmOwn analysis of European submarine HVDC projects since 2000
229HVDC submarine2030lifetime40yearsHagspiel
230HVDC submarine2030FOM2%/yearHagspiel
231HVDC inverter pair2030investment150000EUR/MWHagspiel
232HVDC inverter pair2030lifetime40yearsHagspiel
233HVDC inverter pair2030FOM2%/yearHagspiel