1technologyyearparametervalueunitsource
2solar-rooftop2030discount rate0.04per unitstandard for decentral
3onwind2030lifetime30yearsDEA https://ens.dk/en/our-services/projections-and-models/technology-data
4offwind2030lifetime30yearsDEA https://ens.dk/en/our-services/projections-and-models/technology-data
5solar2030lifetime25yearsIEA2010
6solar-rooftop2030lifetime25yearsIEA2010
7solar-utility2030lifetime25yearsIEA2010
8PHS2030lifetime80yearsIEA2010
9hydro2030lifetime80yearsIEA2010
10ror2030lifetime80yearsIEA2010
11OCGT2030lifetime30yearsIEA2010
12nuclear2030lifetime45yearsECF2010 in DIW DataDoc http://hdl.handle.net/10419/80348
13CCGT2030lifetime30yearsIEA2010
14coal2030lifetime40yearsIEA2010
15lignite2030lifetime40yearsIEA2010
16geothermal2030lifetime40yearsIEA2010
17biomass2030lifetime30yearsECF2010 in DIW DataDoc http://hdl.handle.net/10419/80348
18oil2030lifetime30yearsECF2010 in DIW DataDoc http://hdl.handle.net/10419/80348
19onwind2030investment1110EUR/kWelDEA https://ens.dk/en/our-services/projections-and-models/technology-data
20onwind-landcosts2030investment200EUR/kWelLand costs and compensation payments conservatively estimated based on DEA https://ens.dk/en/our-services/projections-and-models/technology-data
21offwind2030investment1640EUR/kWelDEA https://ens.dk/en/our-services/projections-and-models/technology-data
22offwind-ac-station2030investment250EUR/kWelDEA https://ens.dk/en/our-services/projections-and-models/technology-data
23offwind-ac-connection-submarine2030investment2685EUR/MW/kmDEA https://ens.dk/en/our-services/projections-and-models/technology-data
24offwind-ac-connection-underground2030investment1342EUR/MW/kmDEA https://ens.dk/en/our-services/projections-and-models/technology-data
25offwind-dc-station2030investment400EUR/kWelHaertel 2017; assuming one onshore and one offshore node + 13% learning reduction
26offwind-dc-connection-submarine2030investment2000EUR/MW/kmDTU report based on Fig 34 of https://ec.europa.eu/energy/sites/ener/files/documents/2014_nsog_report.pdf
27offwind-dc-connection-underground2030investment1000EUR/MW/kmHaertel 2017; average + 13% learning reduction
28solar2030investment600EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
29biomass2030investment2209EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
30geothermal2030investment3392EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
31coal2030investment1300EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348 PC (Advanced/SuperC)
32lignite2030investment1500EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
33solar-rooftop2030investment725EUR/kWelETIP PV
34solar-utility2030investment425EUR/kWelETIP PV
35PHS2030investment2000EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
36hydro2030investment2000EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
37ror2030investment3000EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
38OCGT2030investment400EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
39nuclear2030investment6000EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
40CCGT2030investment800EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
41oil2030investment400EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
42onwind2030FOM2.450549%/yearDEA https://ens.dk/en/our-services/projections-and-models/technology-data
43offwind2030FOM2.304878%/yearDEA https://ens.dk/en/our-services/projections-and-models/technology-data
44solar2030FOM4.166667%/yearDIW DataDoc http://hdl.handle.net/10419/80348
45solar-rooftop2030FOM2%/yearETIP PV
46solar-utility2030FOM3%/yearETIP PV
47biomass2030FOM4.526935%/yearDIW DataDoc http://hdl.handle.net/10419/80348
48geothermal2030FOM2.358491%/yearDIW DataDoc http://hdl.handle.net/10419/80348
49coal2030FOM1.923076%/yearDIW DataDoc http://hdl.handle.net/10419/80348 PC (Advanced/SuperC)
50lignite2030FOM2.0%/yearDIW DataDoc http://hdl.handle.net/10419/80348 PC (Advanced/SuperC)
51oil2030FOM1.5%/yearDIW DataDoc http://hdl.handle.net/10419/80348
52PHS2030FOM1%/yearDIW DataDoc http://hdl.handle.net/10419/80348
53hydro2030FOM1%/yearDIW DataDoc http://hdl.handle.net/10419/80348
54ror2030FOM2%/yearDIW DataDoc http://hdl.handle.net/10419/80348
55CCGT2030FOM2.5%/yearDIW DataDoc http://hdl.handle.net/10419/80348
56OCGT2030FOM3.75%/yearDIW DataDoc http://hdl.handle.net/10419/80348
57onwind2030VOM2.3EUR/MWhelDEA https://ens.dk/en/our-services/projections-and-models/technology-data
58offwind2030VOM2.7EUR/MWhelDEA https://ens.dk/en/our-services/projections-and-models/technology-data
59solar2030VOM0.01EUR/MWhelRES costs made up to fix curtailment order
60coal2030VOM6EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348 PC (Advanced/SuperC)
61lignite2030VOM7EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348
62CCGT2030VOM4EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348
63OCGT2030VOM3EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348
64nuclear2030VOM8EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348
65gas2030fuel21.6EUR/MWhthIEA2011b
66uranium2030fuel3EUR/MWhthDIW DataDoc http://hdl.handle.net/10419/80348
67oil2030VOM3EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348
68nuclear2030fuel3EUR/MWhthIEA2011b
69biomass2030fuel7EUR/MWhthIEA2011b
70coal2030fuel8.4EUR/MWhthIEA2011b
71lignite2030fuel2.9EUR/MWhthIEA2011b
72oil2030fuel50EUR/MWhthIEA WEM2017 97USD/boe = http://www.iea.org/media/weowebsite/2017/WEM_Documentation_WEO2017.pdf
73PHS2030efficiency0.75per unitDIW DataDoc http://hdl.handle.net/10419/80348
74hydro2030efficiency0.9per unitDIW DataDoc http://hdl.handle.net/10419/80348
75ror2030efficiency0.9per unitDIW DataDoc http://hdl.handle.net/10419/80348
76OCGT2030efficiency0.39per unitDIW DataDoc http://hdl.handle.net/10419/80348
77CCGT2030efficiency0.5per unitDIW DataDoc http://hdl.handle.net/10419/80348
78biomass2030efficiency0.468per unitDIW DataDoc http://hdl.handle.net/10419/80348
79geothermal2030efficiency0.239per unitDIW DataDoc http://hdl.handle.net/10419/80348
80nuclear2030efficiency0.337per unitDIW DataDoc http://hdl.handle.net/10419/80348
81gas2030CO2 intensity0.187tCO2/MWthhttps://www.eia.gov/environment/emissions/co2_vol_mass.php
82coal2030efficiency0.464per unitDIW DataDoc http://hdl.handle.net/10419/80348 PC (Advanced/SuperC)
83lignite2030efficiency0.447per unitDIW DataDoc http://hdl.handle.net/10419/80348
84oil2030efficiency0.393per unitDIW DataDoc http://hdl.handle.net/10419/80348 CT
85coal2030CO2 intensity0.354tCO2/MWthhttps://www.eia.gov/environment/emissions/co2_vol_mass.php
86lignite2030CO2 intensity0.334tCO2/MWthhttps://www.eia.gov/environment/emissions/co2_vol_mass.php
87oil2030CO2 intensity0.248tCO2/MWthhttps://www.eia.gov/environment/emissions/co2_vol_mass.php
88geothermal2030CO2 intensity0.026tCO2/MWthhttps://www.eia.gov/environment/emissions/co2_vol_mass.php
89electrolysis2030investment350EUR/kWelPalzer Thesis
90electrolysis2030FOM4%/yearNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
91electrolysis2030lifetime18yearsNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
92electrolysis2030efficiency0.8per unitNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
93fuel cell2030investment339EUR/kWelNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
94fuel cell2030FOM3%/yearNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
95fuel cell2030lifetime20yearsNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
96fuel cell2030efficiency0.58per unitNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013 conservative 2020
97hydrogen storage2030investment11.2USD/kWhbudischak2013
98hydrogen storage2030lifetime20yearsbudischak2013
99methanation2030investment1000EUR/kWH2Schaber thesis
100methanation2030lifetime25yearsSchaber thesis
101methanation2030FOM3%/yearSchaber thesis
102methanation2030efficiency0.6per unitPalzer; Breyer for DAC
103helmeth2030investment1000EUR/kWno source
104helmeth2030lifetime25yearsno source
105helmeth2030FOM3%/yearno source
106helmeth2030efficiency0.8per unitHELMETH press release
107DAC2030investment250EUR/(tCO2/a)Fasihi/Climeworks
108DAC2030lifetime30yearsFasihi
109DAC2030FOM4%/yearFasihi
110battery inverter2030investment411USD/kWelbudischak2013
111battery inverter2030lifetime20yearsbudischak2013
112battery inverter2030efficiency0.81per unitbudischak2013; Lund and Kempton (2008) http://dx.doi.org/10.1016/j.enpol.2008.06.007
113battery inverter2030FOM3%/yearbudischak2013
114battery storage2030investment192USD/kWhbudischak2013
115battery storage2030lifetime15yearsbudischak2013
116decentral air-sourced heat pump2030investment1050EUR/kWthHP; Palzer thesis
117decentral air-sourced heat pump2030lifetime20yearsHP; Palzer thesis
118decentral air-sourced heat pump2030FOM3.5%/yearPalzer thesis
119decentral air-sourced heat pump2030efficiency3per unitdefault for costs
120decentral air-sourced heat pump2030discount rate0.04per unitPalzer thesis
121decentral ground-sourced heat pump2030investment1400EUR/kWthPalzer thesis
122decentral ground-sourced heat pump2030lifetime20yearsPalzer thesis
123decentral ground-sourced heat pump2030FOM3.5%/yearPalzer thesis
124decentral ground-sourced heat pump2030efficiency4per unitdefault for costs
125decentral ground-sourced heat pump2030discount rate0.04per unitPalzer thesis
126central air-sourced heat pump2030investment700EUR/kWthPalzer thesis
127central air-sourced heat pump2030lifetime20yearsPalzer thesis
128central air-sourced heat pump2030FOM3.5%/yearPalzer thesis
129central air-sourced heat pump2030efficiency3per unitdefault for costs
130retrofitting I2030discount rate0.04per unitPalzer thesis
131retrofitting I2030lifetime50yearsPalzer thesis
132retrofitting I2030FOM1%/yearPalzer thesis
133retrofitting I2030investment50EUR/m2/fraction reductionPalzer thesis
134retrofitting II2030discount rate0.04per unitPalzer thesis
135retrofitting II2030lifetime50yearsPalzer thesis
136retrofitting II2030FOM1%/yearPalzer thesis
137retrofitting II2030investment250EUR/m2/fraction reductionPalzer thesis
138water tank charger2030efficiency0.9per unitHP
139water tank discharger2030efficiency0.9per unitHP
140decentral water tank storage2030investment860EUR/m3IWES Interaktion
141decentral water tank storage2030FOM1%/yearHP
142decentral water tank storage2030lifetime20yearsHP
143decentral water tank storage2030discount rate0.04per unitPalzer thesis
144central water tank storage2030investment30EUR/m3IWES Interaktion
145central water tank storage2030FOM1%/yearHP
146central water tank storage2030lifetime40yearsHP
147decentral resistive heater2030investment100EUR/kWhthSchaber thesis
148decentral resistive heater2030lifetime20yearsSchaber thesis
149decentral resistive heater2030FOM2%/yearSchaber thesis
150decentral resistive heater2030efficiency0.9per unitSchaber thesis
151decentral resistive heater2030discount rate0.04per unitPalzer thesis
152central resistive heater2030investment100EUR/kWhthSchaber thesis
153central resistive heater2030lifetime20yearsSchaber thesis
154central resistive heater2030FOM2%/yearSchaber thesis
155central resistive heater2030efficiency0.9per unitSchaber thesis
156decentral gas boiler2030investment175EUR/kWhthPalzer thesis
157decentral gas boiler2030lifetime20yearsPalzer thesis
158decentral gas boiler2030FOM2%/yearPalzer thesis
159decentral gas boiler2030efficiency0.9per unitPalzer thesis
160decentral gas boiler2030discount rate0.04per unitPalzer thesis
161central gas boiler2030investment63EUR/kWhthPalzer thesis
162central gas boiler2030lifetime22yearsPalzer thesis
163central gas boiler2030FOM1%/yearPalzer thesis
164central gas boiler2030efficiency0.9per unitPalzer thesis
165decentral CHP2030lifetime25yearsHP
166decentral CHP2030investment1400EUR/kWelHP
167decentral CHP2030FOM3%/yearHP
168decentral CHP2030discount rate0.04per unitPalzer thesis
169central CHP2030lifetime25yearsHP
170central CHP2030investment650EUR/kWelHP
171central CHP2030FOM3%/yearHP
172decentral solar thermal2030discount rate0.04per unitPalzer thesis
173decentral solar thermal2030FOM1.3%/yearHP
174decentral solar thermal2030investment270000EUR/1000m2HP
175decentral solar thermal2030lifetime20yearsHP
176central solar thermal2030FOM1.4%/yearHP
177central solar thermal2030investment140000EUR/1000m2HP
178central solar thermal2030lifetime20yearsHP
179HVAC overhead2030investment400EUR/MW/kmHagspiel
180HVAC overhead2030lifetime40yearsHagspiel
181HVAC overhead2030FOM2%/yearHagspiel
182HVDC overhead2030investment400EUR/MW/kmHagspiel
183HVDC overhead2030lifetime40yearsHagspiel
184HVDC overhead2030FOM2%/yearHagspiel
185HVDC submarine2030investment2000EUR/MW/kmDTU report based on Fig 34 of https://ec.europa.eu/energy/sites/ener/files/documents/2014_nsog_report.pdf
186HVDC submarine2030lifetime40yearsHagspiel
187HVDC submarine2030FOM2%/yearHagspiel
188HVDC inverter pair2030investment150000EUR/MWHagspiel
189HVDC inverter pair2030lifetime40yearsHagspiel
190HVDC inverter pair2030FOM2%/yearHagspiel