1technologyyearparametervalueunitsource
2solar-rooftop2030discount rate0.04per unitstandard for decentral
3onwind2030lifetime25yearsIEA2010
4offwind2030lifetime25yearsIEA2010
5solar2030lifetime25yearsIEA2010
6solar-rooftop2030lifetime25yearsIEA2010
7solar-utility2030lifetime25yearsIEA2010
8PHS2030lifetime80yearsIEA2010
9hydro2030lifetime80yearsIEA2010
10ror2030lifetime80yearsIEA2010
11OCGT2030lifetime30yearsIEA2010
12nuclear2030lifetime45yearsECF2010 in DIW DataDoc http://hdl.handle.net/10419/80348
13CCGT2030lifetime30yearsIEA2010
14coal2030lifetime40yearsIEA2010
15lignite2030lifetime40yearsIEA2010
16geothermal2030lifetime40yearsIEA2010
17biomass2030lifetime30yearsECF2010 in DIW DataDoc http://hdl.handle.net/10419/80348
18oil2030lifetime30yearsECF2010 in DIW DataDoc http://hdl.handle.net/10419/80348
19onwind2030investment1182EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
20offwind2030investment2506EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
21solar2030investment600EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
22biomass2030investment2209EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
23geothermal2030investment3392EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
24coal2030investment1300EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348 PC (Advanced/SuperC)
25lignite2030investment1500EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
26solar-rooftop2030investment725EUR/kWelETIP PV
27solar-utility2030investment425EUR/kWelETIP PV
28PHS2030investment2000EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
29hydro2030investment2000EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
30ror2030investment3000EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
31OCGT2030investment400EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
32nuclear2030investment6000EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
33CCGT2030investment800EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
34oil2030investment400EUR/kWelDIW DataDoc http://hdl.handle.net/10419/80348
35onwind2030FOM2.961083%/yearDIW DataDoc http://hdl.handle.net/10419/80348
36offwind2030FOM3.192338%/yearDIW DataDoc http://hdl.handle.net/10419/80348
37solar2030FOM4.166667%/yearDIW DataDoc http://hdl.handle.net/10419/80348
38solar-rooftop2030FOM2%/yearETIP PV
39solar-utility2030FOM3%/yearETIP PV
40biomass2030FOM4.526935%/yearDIW DataDoc http://hdl.handle.net/10419/80348
41geothermal2030FOM2.358491%/yearDIW DataDoc http://hdl.handle.net/10419/80348
42coal2030FOM1.923076%/yearDIW DataDoc http://hdl.handle.net/10419/80348 PC (Advanced/SuperC)
43lignite2030FOM2.0%/yearDIW DataDoc http://hdl.handle.net/10419/80348 PC (Advanced/SuperC)
44oil2030FOM1.5%/yearDIW DataDoc http://hdl.handle.net/10419/80348
45PHS2030FOM1%/yearDIW DataDoc http://hdl.handle.net/10419/80348
46hydro2030FOM1%/yearDIW DataDoc http://hdl.handle.net/10419/80348
47ror2030FOM2%/yearDIW DataDoc http://hdl.handle.net/10419/80348
48CCGT2030FOM2.5%/yearDIW DataDoc http://hdl.handle.net/10419/80348
49OCGT2030FOM3.75%/yearDIW DataDoc http://hdl.handle.net/10419/80348
50onwind2030VOM0.015EUR/MWhelRES costs made up to fix curtailment order
51offwind2030VOM0.02EUR/MWhelRES costs made up to fix curtailment order
52solar2030VOM0.01EUR/MWhelRES costs made up to fix curtailment order
53coal2030VOM6EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348 PC (Advanced/SuperC)
54lignite2030VOM7EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348
55CCGT2030VOM4EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348
56OCGT2030VOM3EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348
57nuclear2030VOM8EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348
58gas2030fuel21.6EUR/MWhthIEA2011b
59uranium2030fuel3EUR/MWhthDIW DataDoc http://hdl.handle.net/10419/80348
60oil2030VOM3EUR/MWhelDIW DataDoc http://hdl.handle.net/10419/80348
61nuclear2030fuel3EUR/MWhthIEA2011b
62biomass2030fuel7EUR/MWhthIEA2011b
63coal2030fuel8.4EUR/MWhthIEA2011b
64lignite2030fuel2.9EUR/MWhthIEA2011b
65biogas2030fuel59EUR/MWhthJRC and Zappa
66solid biomass2030fuel25.2EUR/MWhthJRC and Zappa
67oil2030fuel50EUR/MWhthIEA WEM2017 97USD/boe = http://www.iea.org/media/weowebsite/2017/WEM_Documentation_WEO2017.pdf
68PHS2030efficiency0.75per unitDIW DataDoc http://hdl.handle.net/10419/80348
69hydro2030efficiency0.9per unitDIW DataDoc http://hdl.handle.net/10419/80348
70ror2030efficiency0.9per unitDIW DataDoc http://hdl.handle.net/10419/80348
71OCGT2030efficiency0.39per unitDIW DataDoc http://hdl.handle.net/10419/80348
72CCGT2030efficiency0.5per unitDIW DataDoc http://hdl.handle.net/10419/80348
73biomass2030efficiency0.468per unitDIW DataDoc http://hdl.handle.net/10419/80348
74geothermal2030efficiency0.239per unitDIW DataDoc http://hdl.handle.net/10419/80348
75nuclear2030efficiency0.337per unitDIW DataDoc http://hdl.handle.net/10419/80348
76gas2030CO2 intensity0.187tCO2/MWthhttps://www.eia.gov/environment/emissions/co2_vol_mass.php
77coal2030efficiency0.464per unitDIW DataDoc http://hdl.handle.net/10419/80348 PC (Advanced/SuperC)
78lignite2030efficiency0.447per unitDIW DataDoc http://hdl.handle.net/10419/80348
79oil2030efficiency0.393per unitDIW DataDoc http://hdl.handle.net/10419/80348 CT
80coal2030CO2 intensity0.354tCO2/MWthhttps://www.eia.gov/environment/emissions/co2_vol_mass.php
81lignite2030CO2 intensity0.4tCO2/MWthGerman sources
82oil2030CO2 intensity0.248tCO2/MWthhttps://www.eia.gov/environment/emissions/co2_vol_mass.php
83geothermal2030CO2 intensity0.026tCO2/MWthhttps://www.eia.gov/environment/emissions/co2_vol_mass.php
84solid biomass2030CO2 intensity0.3tCO2/MWthTODO
85electrolysis2030investment350EUR/kWelPalzer Thesis
86electrolysis2030FOM4%/yearNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
87electrolysis2030lifetime18yearsNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
88electrolysis2030efficiency0.8per unitNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
89fuel cell2030investment339EUR/kWelNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
90fuel cell2030FOM3%/yearNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
91fuel cell2030lifetime20yearsNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013
92fuel cell2030efficiency0.58per unitNREL http://www.nrel.gov/docs/fy09osti/45873.pdf; budischak2013 conservative 2020
93hydrogen storage2030investment11.2USD/kWhbudischak2013
94hydrogen storage2030lifetime20yearsbudischak2013
95hydrogen underground storage2030investment0.5EUR/kWhmaximum from https://www.nrel.gov/docs/fy10osti/46719.pdf
96hydrogen underground storage2030lifetime40yearshttp://www.acatech.de/fileadmin/user_upload/Baumstruktur_nach_Website/Acatech/root/de/Publikationen/Materialien/ESYS_Technologiesteckbrief_Energiespeicher.pdf
97methanation2030investment1000EUR/kWH2Schaber thesis
98methanation2030lifetime25yearsSchaber thesis
99methanation2030FOM3%/yearSchaber thesis
100methanation2030efficiency0.8per unitPalzer and Schaber thesis
101helmeth2030investment2000EUR/kWno source
102helmeth2030lifetime25yearsno source
103helmeth2030FOM3%/yearno source
104helmeth2030efficiency0.8per unitHELMETH press release
105SMR2030investment540.56EUR/kWCH4https://www.gov.uk/government/publications/hydrogen-supply-chain-evidence-base; slide 42 assumption for 2030; GBP 466 exchange 1.16
106SMR2030lifetime25yearsTODO
107SMR2030FOM5.4%/yearhttps://www.gov.uk/government/publications/hydrogen-supply-chain-evidence-base; slide 42 assumption for 2030
108SMR2030efficiency0.74per unithttps://www.gov.uk/government/publications/hydrogen-supply-chain-evidence-base; slide 42 assumption for 2030
109Fischer-Tropsch2030investment677.6EUR/kWH2Fasihi doi:10.3390/su9020306 (60 kEUR/bpd = 847 EUR/kWL (1b = 1.7 MWh) 847*0.8 = 677.6)
110Fischer-Tropsch2030lifetime30yearsdoi:10.3390/su9020306
111Fischer-Tropsch2030FOM3%/yeardoi:10.3390/su9020306
112Fischer-Tropsch2030efficiency0.8per unitTODO
113DAC2030investment250EUR/(tCO2/a)Fasihi doi:10.3390/su9020306/Climeworks
114DAC2030lifetime30yearsFasihi
115DAC2030FOM4%/yearFasihi
116battery inverter2030investment411USD/kWelbudischak2013
117battery inverter2030lifetime20yearsbudischak2013
118battery inverter2030efficiency0.81per unitbudischak2013; Lund and Kempton (2008) http://dx.doi.org/10.1016/j.enpol.2008.06.007
119battery inverter2030FOM3%/yearbudischak2013
120battery storage2030investment192USD/kWhbudischak2013
121battery storage2030lifetime15yearsbudischak2013
122decentral air-sourced heat pump2030investment1050EUR/kWthHP; Palzer thesis
123decentral air-sourced heat pump2030lifetime20yearsHP; Palzer thesis
124decentral air-sourced heat pump2030FOM3.5%/yearPalzer thesis
125decentral air-sourced heat pump2030efficiency3per unitdefault for costs
126decentral air-sourced heat pump2030discount rate0.04per unitPalzer thesis
127decentral ground-sourced heat pump2030investment1400EUR/kWthPalzer thesis
128decentral ground-sourced heat pump2030lifetime20yearsPalzer thesis
129decentral ground-sourced heat pump2030FOM3.5%/yearPalzer thesis
130decentral ground-sourced heat pump2030efficiency4per unitdefault for costs
131decentral ground-sourced heat pump2030discount rate0.04per unitPalzer thesis
132central air-sourced heat pump2030investment700EUR/kWthPalzer thesis
133central air-sourced heat pump2030lifetime20yearsPalzer thesis
134central air-sourced heat pump2030FOM3.5%/yearPalzer thesis
135central air-sourced heat pump2030efficiency3per unitdefault for costs
136retrofitting I2030discount rate0.04per unitPalzer thesis
137retrofitting I2030lifetime50yearsPalzer thesis
138retrofitting I2030FOM1%/yearPalzer thesis
139retrofitting I2030investment50EUR/m2/fraction reductionPalzer thesis
140retrofitting II2030discount rate0.04per unitPalzer thesis
141retrofitting II2030lifetime50yearsPalzer thesis
142retrofitting II2030FOM1%/yearPalzer thesis
143retrofitting II2030investment250EUR/m2/fraction reductionPalzer thesis
144water tank charger2030efficiency0.9per unitHP
145water tank discharger2030efficiency0.9per unitHP
146decentral water tank storage2030investment860EUR/m3IWES Interaktion
147decentral water tank storage2030FOM1%/yearHP
148decentral water tank storage2030lifetime20yearsHP
149decentral water tank storage2030discount rate0.04per unitPalzer thesis
150central water tank storage2030investment30EUR/m3IWES Interaktion
151central water tank storage2030FOM1%/yearHP
152central water tank storage2030lifetime40yearsHP
153decentral resistive heater2030investment100EUR/kWhthSchaber thesis
154decentral resistive heater2030lifetime20yearsSchaber thesis
155decentral resistive heater2030FOM2%/yearSchaber thesis
156decentral resistive heater2030efficiency0.9per unitSchaber thesis
157decentral resistive heater2030discount rate0.04per unitPalzer thesis
158central resistive heater2030investment100EUR/kWhthSchaber thesis
159central resistive heater2030lifetime20yearsSchaber thesis
160central resistive heater2030FOM2%/yearSchaber thesis
161central resistive heater2030efficiency0.9per unitSchaber thesis
162decentral gas boiler2030investment175EUR/kWhthPalzer thesis
163decentral gas boiler2030lifetime20yearsPalzer thesis
164decentral gas boiler2030FOM2%/yearPalzer thesis
165decentral gas boiler2030efficiency0.9per unitPalzer thesis
166decentral gas boiler2030discount rate0.04per unitPalzer thesis
167central gas boiler2030investment63EUR/kWhthPalzer thesis
168central gas boiler2030lifetime22yearsPalzer thesis
169central gas boiler2030FOM1%/yearPalzer thesis
170central gas boiler2030efficiency0.9per unitPalzer thesis
171decentral CHP2030lifetime25yearsHP
172decentral CHP2030investment1400EUR/kWelHP
173decentral CHP2030FOM3%/yearHP
174decentral CHP2030discount rate0.04per unitPalzer thesis
175central CHP2030lifetime25yearsHP
176central CHP2030investment650EUR/kWelHP
177central CHP2030FOM3%/yearHP
178decentral solar thermal2030discount rate0.04per unitPalzer thesis
179decentral solar thermal2030FOM1.3%/yearHP
180decentral solar thermal2030investment270000EUR/1000m2HP
181decentral solar thermal2030lifetime20yearsHP
182central solar thermal2030FOM1.4%/yearHP
183central solar thermal2030investment140000EUR/1000m2HP
184central solar thermal2030lifetime20yearsHP
185HVAC overhead2030investment400EUR/MW/kmHagspiel
186HVAC overhead2030lifetime40yearsHagspiel
187HVAC overhead2030FOM2%/yearHagspiel
188HVDC overhead2030investment400EUR/MW/kmHagspiel
189HVDC overhead2030lifetime40yearsHagspiel
190HVDC overhead2030FOM2%/yearHagspiel
191HVDC submarine2030investment2000EUR/MW/kmOwn analysis of European submarine HVDC projects since 2000
192HVDC submarine2030lifetime40yearsHagspiel
193HVDC submarine2030FOM2%/yearHagspiel
194HVDC inverter pair2030investment150000EUR/MWHagspiel
195HVDC inverter pair2030lifetime40yearsHagspiel
196HVDC inverter pair2030FOM2%/yearHagspiel