@ -126,7 +126,7 @@ The coefficient of performance (COP) of air- and ground-sourced heat pumps depen
|
||||
.. math::
|
||||
\Delta T = T_{sink} − T_{source}
|
||||
|
||||
For the sink water temperature Tsink we assume 55 °C [`Config <https://github.com/PyPSA/pypsa-eur-sec/blob/3daff49c9999ba7ca7534df4e587e1d516044fc3/config.default.yaml#L207>`_ file] For the time- and location-dependent source temperatures Tsource, we rely on the `ERA5 <https://doi.org/10.1002/qj.3803>`_ reanalysis weather data. The temperature differences are converted into COP time series using results from a regression analysis performed in the study by `Stafell et al. <https://pubs.rsc.org/en/content/articlelanding/2012/EE/c2ee22653g>`_. For air-sourced heat pumps (ASHP), we use the function:
|
||||
For the sink water temperature Tsink we assume 55 °C [`Config <https://github.com/PyPSA/pypsa-eur-sec/blob/3daff49c9999ba7ca7534df4e587e1d516044fc3/config.default.yaml#L207>`_ file]. For the time- and location-dependent source temperatures Tsource, we rely on the `ERA5 <https://doi.org/10.1002/qj.3803>`_ reanalysis weather data. The temperature differences are converted into COP time series using results from a regression analysis performed in the study by `Stafell et al. <https://pubs.rsc.org/en/content/articlelanding/2012/EE/c2ee22653g>`_. For air-sourced heat pumps (ASHP), we use the function:
|
||||
|
||||
.. math::
|
||||
COP (\Delta T) = 6.81 + 0.121\Delta T + 0.000630\Delta T^2
|
||||
|