From f3ef8011f42d7cba64fee5e4db81cffe567a68d4 Mon Sep 17 00:00:00 2001 From: martavp <30744159+martavp@users.noreply.github.com> Date: Sun, 27 Nov 2022 12:59:58 +0100 Subject: [PATCH] Update doc/supply_demand.rst Co-authored-by: energyLS <89515385+energyLS@users.noreply.github.com> --- doc/supply_demand.rst | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/doc/supply_demand.rst b/doc/supply_demand.rst index 6cf1512f..e2597d1e 100644 --- a/doc/supply_demand.rst +++ b/doc/supply_demand.rst @@ -126,7 +126,7 @@ The coefficient of performance (COP) of air- and ground-sourced heat pumps depen .. math:: \Delta T = T_{sink} − T_{source} -For the sink water temperature Tsink we assume 55 °C [`Config `_ file] For the time- and location-dependent source temperatures Tsource, we rely on the `ERA5 `_ reanalysis weather data. The temperature differences are converted into COP time series using results from a regression analysis performed in the study by `Stafell et al. `_. For air-sourced heat pumps (ASHP), we use the function: +For the sink water temperature Tsink we assume 55 °C [`Config `_ file]. For the time- and location-dependent source temperatures Tsource, we rely on the `ERA5 `_ reanalysis weather data. The temperature differences are converted into COP time series using results from a regression analysis performed in the study by `Stafell et al. `_. For air-sourced heat pumps (ASHP), we use the function: .. math:: COP (\Delta T) = 6.81 + 0.121\Delta T + 0.000630\Delta T^2