pypsa-eur/config.yaml

93 lines
2.8 KiB
YAML

results_dir: 'results/'
summary_dir: results
run: '190416-modular-test'
scenario:
sectors: [E] # ,E+EV,E+BEV,E+BEV+V2G] # [ E+EV, E+BEV, E+BEV+V2G ]
simpl: ['']
lv: [1.0]#[1.0, 1.125, 1.25, 1.5, 2.0, opt]# or opt
clusters: [128] #[90, 128, 181] #[45, 64, 90, 128, 181, 256] #, 362] # (2**np.r_[5.5:9:.5]).astype(int) minimum is 37
opts: [Co2L0-3H-T-H-B-I,Co2L0-3H-T-H-B-I-onwind0,Co2L0-3H-T-H-B-I-onwind0p1]#,Co2L0p05-3H-T-H-B-I,Co2L0p10-3H-T-H-B-I,Co2L0p20-3H-T-H-B-I,Co2L0p30-3H-T-H-B-I,Co2L0p50-3H-T-H-B-I]#[Co2L-3H-T-H,Co2L0p10-3H-T-H,Co2L0-3H-T-H,Co2L0p20-3H-T-H] #Co2L-3H-T-H,Co2L0p10-3H-T-H,Co2L0p20-3H-T-HCo2L-3H-T-H,Co2L0p10-3H-T-H,Co2L0p30-3H-T-H,Co2L0p50-3H-T-H] #Co2L-3H,Co2L-3H-T,, LC-FL, LC-T, Ep-T, Co2L-T]
# Co2L will give default (5%); Co2L0p25 will give 25% CO2 emissions; Co2Lm0p05 will give 5% negative emissions
snapshots:
# arguments to pd.date_range
start: "2013-01-01"
end: "2014-01-01"
closed: 'left' # end is not inclusive
atlite:
nprocesses: 4
cutout_dir: '../pypsa-eur/cutouts'
cutouts:
europe-2013-era5:
module: era5
xs: [-12., 35.]
ys: [72., 33.]
years: [2013, 2013]
europe-2013-sarah:
module: sarah
resolution: 0.2
xs: [-12., 42.]
ys: [65., 33.]
years: [2013, 2013]
renewable:
onwind:
cutout: europe-2013-era5
resource:
method: wind
turbine: Vestas_V112_3MW
# ScholzPhd Tab 4.3.1: 10MW/km^2
capacity_per_sqm: 3
# correction_factor: 0.93
corine:
#The selection of CORINE Land Cover [1] types that are allowed for wind and solar are based on [2] p.42 / p.28
#
#[1] https://www.eea.europa.eu/ds_resolveuid/C9RK15EA06
#
#[2] Scholz, Y. (2012). Renewable energy based electricity supply at low costs: development of the REMix model and application for Europe.
grid_codes: [12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23,
24, 25, 26, 27, 28, 29, 31, 32]
distance: 1000
distance_grid_codes: [1, 2, 3, 4, 5, 6]
natura: true
offwind:
cutout: europe-2013-era5
resource:
method: wind
turbine: NREL_ReferenceTurbine_5MW_offshore
# ScholzPhd Tab 4.3.1: 10MW/km^2
capacity_per_sqm: 3
height_cutoff: 50
# correction_factor: 0.93
corine:
grid_codes: [44, 255]
natura: true
solar:
cutout: europe-2013-sarah
resource:
method: pv
panel: CSi
orientation:
slope: 35.
azimuth: 180.
# ScholzPhd Tab 4.3.1: 170 MW/km^2
capacity_per_sqm: 1.7
correction_factor: 0.877
corine:
grid_codes: [1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17,
18, 19, 20, 26, 31, 32]
natura: true
hydro:
cutout: europe-2013-era5
carriers: [ror, PHS, hydro]
PHS_max_hours: 6
biomass:
year: 2030
scenario: "Med"