pypsa-eur/config.default.yaml
Tom Brown 791a58fc6b Make selection of biomass classes (solid, biogas) more explicit
List classes in config.yaml, rather than integer selection in
build_biomass_potentials.py.

Also output potentials for all years and scenarios for analysis.
2020-09-21 18:35:45 +02:00

339 lines
12 KiB
YAML
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

version: 0.2.0
logging_level: INFO
results_dir: 'results/'
summary_dir: results
costs_dir: '../technology-data/outputs/'
run: 'your-run-name' # use this to keep track of runs with different settings
foresight: 'overnight' #options are overnight, myopic, perfect (perfect is not yet implemented)
scenario:
sectors: [E] # ignore this legacy setting
simpl: [''] # only relevant for PyPSA-Eur
lv: [1.0,1.5] # allowed transmission line volume expansion, can be any float >= 1.0 (today) or "opt"
clusters: [45,50] # number of nodes in Europe, any integer between 37 (1 node per country-zone) and several hundred
opts: [''] # only relevant for PyPSA-Eur
sector_opts: [Co2L0-3H-T-H-B-I-solar3-dist1] # this is where the main scenario settings are
# to really understand the options here, look in scripts/prepare_sector_network.py
# Co2Lx specifies the CO2 target in x% of the 1990 values; default will give default (5%);
# Co2L0p25 will give 25% CO2 emissions; Co2Lm0p05 will give 5% negative emissions
# xH is the temporal resolution; 3H is 3-hourly, i.e. one snapshot every 3 hours
# single letters are sectors: T for land transport, H for building heating,
# B for biomass supply, I for industry, shipping and aviation
# solarx or onwindx changes the available installable potential by factor x
# dist{n} includes distribution grids with investment cost of n times cost in data/costs.csv
planning_horizons : [2030] #investment years for myopic and perfect; or costs year for overnight
co2_budget_name: ['go'] #gives shape of CO2 budgets over planning horizon
# snapshots are originally set in PyPSA-Eur/config.yaml but used again by PyPSA-Eur-Sec
snapshots:
# arguments to pd.date_range
start: "2013-01-01"
end: "2014-01-01"
closed: 'left' # end is not inclusive
atlite:
cutout_dir: '../pypsa-eur/cutouts'
cutout_name: "europe-2013-era5"
# this information is NOT used but needed as an argument for
# pypsa-eur/scripts/add_electricity.py/load_costs in make_summary.py
electricity:
max_hours:
battery: 6
H2: 168
biomass:
year: 2030
scenario: "Med"
classes:
solid biomass: ['Primary agricultural residues', 'Forestry energy residue', 'Secondary forestry residues', 'Secondary Forestry residues sawdust', 'Forestry residues from landscape care biomass', 'Municipal waste']
not included: ['Bioethanol sugar beet biomass', 'Rapeseeds for biodiesel', 'sunflower and soya for Biodiesel', 'Starchy crops biomass', 'Grassy crops biomass', 'Willow biomass', 'Poplar biomass potential', 'Roundwood fuelwood', 'Roundwood Chips & Pellets']
biogas: ['Manure biomass potential', 'Sludge biomass']
# only relevant for foresight = myopic or perfect
existing_capacities:
grouping_years: [1980, 1985, 1990, 1995, 2000, 2005, 2010, 2015, 2019]
threshold_capacity: 10
conventional_carriers: ['lignite', 'coal', 'oil', 'uranium']
sector:
'central' : True
'central_fraction' : 0.6
'dsm_restriction_value' : 0.75 #Set to 0 for no restriction on BEV DSM
'dsm_restriction_time' : 7 #Time at which SOC of BEV has to be dsm_restriction_value
'transport_heating_deadband_upper' : 20.
'transport_heating_deadband_lower' : 15.
'ICE_lower_degree_factor' : 0.375 #in per cent increase in fuel consumption per degree above deadband
'ICE_upper_degree_factor' : 1.6
'EV_lower_degree_factor' : 0.98
'EV_upper_degree_factor' : 0.63
'district_heating_loss' : 0.15
'bev' : True #turns on EV battery
'bev_availability' : 0.5 #How many cars do smart charging
'v2g' : True #allows feed-in to grid from EV battery
'transport_fuel_cell_share' : 0. #0 means all EVs, 1 means all FCs
'shipping_average_efficiency' : 0.4 #For conversion of fuel oil to propulsion in 2011
'time_dep_hp_cop' : True
'space_heating_fraction' : 1.0 #fraction of space heating active
'retrofitting' : False
'retroI-fraction' : 0.25
'retroII-fraction' : 0.55
'retrofitting-cost_factor' : 1.0
'tes' : True
'tes_tau' : 3.
'boilers' : True
'oil_boilers': False
'chp' : True
'solar_thermal' : True
'solar_cf_correction': 0.788457 # = >>> 1/1.2683
'marginal_cost_storage' : 0. #1e-4
'methanation' : True
'helmeth' : True
'dac' : True
'co2_vent' : True
'SMR' : True
'ccs_fraction' : 0.9
'hydrogen_underground_storage' : True
'use_fischer_tropsch_waste_heat' : True
'use_fuel_cell_waste_heat' : True
'electricity_distribution_grid' : False
'electricity_distribution_grid_cost_factor' : 1.0 #multiplies cost in data/costs.csv
'electricity_grid_connection' : True # only applies to onshore wind and utility PV
costs:
year: 2030
lifetime: 25 #default lifetime
# From a Lion Hirth paper, also reflects average of Noothout et al 2016
discountrate: 0.07
# [EUR/USD] ECB: https://www.ecb.europa.eu/stats/exchange/eurofxref/html/eurofxref-graph-usd.en.html # noqa: E501
USD2013_to_EUR2013: 0.7532
# Marginal and capital costs can be overwritten
# capital_cost:
# Wind: Bla
marginal_cost: #
solar: 0.01
onwind: 0.015
offwind: 0.015
hydro: 0.
H2: 0.
battery: 0.
emission_prices: # only used with the option Ep (emission prices)
co2: 0.
lines:
length_factor: 1.25 #to estimate offwind connection costs
solving:
#tmpdir: "path/to/tmp"
options:
formulation: kirchhoff
clip_p_max_pu: 1.e-2
load_shedding: false
noisy_costs: true
min_iterations: 1
max_iterations: 1
# nhours: 1
solver:
name: gurobi
threads: 4
method: 2 # barrier
crossover: 0
BarConvTol: 1.e-5
Seed: 123
AggFill: 0
PreDual: 0
GURO_PAR_BARDENSETHRESH: 200
#FeasibilityTol: 1.e-6
#name: cplex
#threads: 4
#lpmethod: 4 # barrier
#solutiontype: 2 # non basic solution, ie no crossover
#barrier_convergetol: 1.e-5
#feasopt_tolerance: 1.e-6
mem: 30000 #memory in MB; 20 GB enough for 50+B+I+H2; 100 GB for 181+B+I+H2
industry:
'St_primary_fraction' : 0.3 # fraction of steel produced via primary route (DRI + EAF) versus secondary route (EAF); today fraction is 0.6
'H2_DRI' : 1.7 #H2 consumption in Direct Reduced Iron (DRI), MWh_H2,LHV/ton_Steel from Vogl et al (2018) doi:10.1016/j.jclepro.2018.08.279
'elec_DRI' : 0.322 #electricity consumption in Direct Reduced Iron (DRI) shaft, MWh/tSt HYBRIT brochure https://ssabwebsitecdn.azureedge.net/-/media/hybrit/files/hybrit_brochure.pdf
'Al_primary_fraction' : 0.2 # fraction of aluminium produced via the primary route versus scrap; today fraction is 0.4
'MWh_CH4_per_tNH3_SMR' : 10.8 # 2012's demand from https://ec.europa.eu/docsroom/documents/4165/attachments/1/translations/en/renditions/pdf
'MWh_elec_per_tNH3_SMR' : 0.7 # same source, assuming 94-6% split methane-elec of total energy demand 11.5 MWh/tNH3
'MWh_H2_per_tNH3_electrolysis' : 6.5 # from https://doi.org/10.1016/j.joule.2018.04.017, around 0.197 tH2/tHN3 (>3/17 since some H2 lost and used for energy)
'MWh_elec_per_tNH3_electrolysis' : 1.17 # from https://doi.org/10.1016/j.joule.2018.04.017 Table 13 (air separation and HB)
'NH3_process_emissions' : 24.5 # in MtCO2/a from SMR for H2 production for NH3 from UNFCCC for 2015 for EU28
'petrochemical_process_emissions' : 25.5 # in MtCO2/a for petrochemical and other from UNFCCC for 2015 for EU28
plotting:
map:
figsize: [7, 7]
boundaries: [-10.2, 29, 35, 72]
p_nom:
bus_size_factor: 5.e+4
linewidth_factor: 3.e+3 # 1.e+3 #3.e+3
costs_max: 1200
costs_threshold: 1
energy_max: 20000.
energy_min: -15000.
energy_threshold: 50.
vre_techs: ["onwind", "offwind-ac", "offwind-dc", "solar", "ror"]
renewable_storage_techs: ["PHS","hydro"]
conv_techs: ["OCGT", "CCGT", "Nuclear", "Coal"]
storage_techs: ["hydro+PHS", "battery", "H2"]
# store_techs: ["Li ion", "water tanks"]
load_carriers: ["AC load"] #, "heat load", "Li ion load"]
AC_carriers: ["AC line", "AC transformer"]
link_carriers: ["DC line", "Converter AC-DC"]
heat_links: ["heat pump", "resistive heater", "CHP heat", "CHP electric",
"gas boiler", "central heat pump", "central resistive heater", "central CHP heat",
"central CHP electric", "central gas boiler"]
heat_generators: ["gas boiler", "central gas boiler", "solar thermal collector", "central solar thermal collector"]
tech_colors:
"onwind" : "b"
"onshore wind" : "b"
'offwind' : "c"
'offshore wind' : "c"
'offwind-ac' : "c"
'offshore wind (AC)' : "c"
'offwind-dc' : "#009999"
'offshore wind (DC)' : "#009999"
'wave' : "#004444"
"hydro" : "#3B5323"
"hydro reservoir" : "#3B5323"
"ror" : "#78AB46"
"run of river" : "#78AB46"
'hydroelectricity' : '#006400'
'solar' : "y"
'solar PV' : "y"
'solar thermal' : 'coral'
'solar rooftop' : '#e6b800'
"OCGT" : "wheat"
"OCGT marginal" : "sandybrown"
"OCGT-heat" : "orange"
"gas boiler" : "orange"
"gas boilers" : "orange"
"gas boiler marginal" : "orange"
"gas-to-power/heat" : "orange"
"gas" : "brown"
"natural gas" : "brown"
"SMR" : "#4F4F2F"
"oil" : "#B5A642"
"oil boiler" : "#B5A677"
"lines" : "k"
"transmission lines" : "k"
"H2" : "m"
"hydrogen storage" : "m"
"battery" : "slategray"
"battery storage" : "slategray"
"home battery" : "#614700"
"home battery storage" : "#614700"
"Nuclear" : "r"
"Nuclear marginal" : "r"
"nuclear" : "r"
"uranium" : "r"
"Coal" : "k"
"coal" : "k"
"Coal marginal" : "k"
"Lignite" : "grey"
"lignite" : "grey"
"Lignite marginal" : "grey"
"CCGT" : "orange"
"CCGT marginal" : "orange"
"heat pumps" : "#76EE00"
"heat pump" : "#76EE00"
"air heat pump" : "#76EE00"
"ground heat pump" : "#40AA00"
"power-to-heat" : "#40AA00"
"resistive heater" : "pink"
"Sabatier" : "#FF1493"
"methanation" : "#FF1493"
"power-to-gas" : "#FF1493"
"power-to-liquid" : "#FFAAE9"
"helmeth" : "#7D0552"
"helmeth" : "#7D0552"
"DAC" : "#E74C3C"
"co2 stored" : "#123456"
"CO2 sequestration" : "#123456"
"CCS" : "k"
"co2" : "#123456"
"co2 vent" : "#654321"
"solid biomass for industry co2 from atmosphere" : "#654321"
"solid biomass for industry co2 to stored": "#654321"
"gas for industry co2 to atmosphere": "#654321"
"gas for industry co2 to stored": "#654321"
"Fischer-Tropsch" : "#44DD33"
"kerosene for aviation": "#44BB11"
"naphtha for industry" : "#44FF55"
"water tanks" : "#BBBBBB"
"hot water storage" : "#BBBBBB"
"hot water charging" : "#BBBBBB"
"hot water discharging" : "#999999"
"CHP" : "r"
"CHP heat" : "r"
"CHP electric" : "r"
"PHS" : "g"
"Ambient" : "k"
"Electric load" : "b"
"Heat load" : "r"
"Transport load" : "grey"
"heat" : "darkred"
"rural heat" : "#880000"
"central heat" : "#b22222"
"decentral heat" : "#800000"
"low-temperature heat for industry" : "#991111"
"process heat" : "#FF3333"
"heat demand" : "darkred"
"electric demand" : "k"
"Li ion" : "grey"
"district heating" : "#CC4E5C"
"retrofitting" : "purple"
"building retrofitting" : "purple"
"BEV charger" : "grey"
"V2G" : "grey"
"transport" : "grey"
"electricity" : "k"
"gas for industry" : "#333333"
"solid biomass for industry" : "#555555"
"industry new electricity" : "#222222"
"process emissions to stored" : "#444444"
"process emissions to atmosphere" : "#888888"
"process emissions" : "#222222"
"transport fuel cell" : "#AAAAAA"
"biogas" : "#800000"
"solid biomass" : "#DAA520"
"today" : "#D2691E"
"shipping" : "#6495ED"
"electricity distribution grid" : "#333333"
nice_names:
# OCGT: "Gas"
# OCGT marginal: "Gas (marginal)"
offwind: "offshore wind"
onwind: "onshore wind"
battery: "Battery storage"
lines: "Transmission lines"
AC line: "AC lines"
AC-AC: "DC lines"
ror: "Run of river"
nice_names_n:
offwind: "offshore\nwind"
onwind: "onshore\nwind"
# OCGT: "Gas"
H2: "Hydrogen\nstorage"
# OCGT marginal: "Gas (marginal)"
lines: "transmission\nlines"