pypsa-eur/config/config.default.yaml
Tom Brown 6d94439bbb for existing heating use new default_heating_lifetime
This is because old costs default (25) is longer than all heating
technologies (20). Script was distributing across 25 years, then
throwing out boilers older than 20 years, an inconsistent
behaviour.

Now existing boilers are smoothly distributed across 20 years.
2024-02-07 17:15:37 +01:00

1100 lines
30 KiB
YAML

# SPDX-FileCopyrightText: : 2017-2023 The PyPSA-Eur Authors
#
# SPDX-License-Identifier: CC0-1.0
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#top-level-configuration
version: 0.9.0
tutorial: false
logging:
level: INFO
format: '%(levelname)s:%(name)s:%(message)s'
private:
keys:
entsoe_api:
remote:
ssh: ""
path: ""
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#run
run:
name: ""
disable_progressbar: false
shared_resources: false
shared_cutouts: true
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#foresight
foresight: overnight
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#scenario
# Wildcard docs in https://pypsa-eur.readthedocs.io/en/latest/wildcards.html
scenario:
simpl:
- ''
ll:
- v1.5
clusters:
- 37
- 128
- 256
- 512
- 1024
opts:
- ''
sector_opts:
- Co2L0-3H-T-H-B-I-A-dist1
planning_horizons:
# - 2020
# - 2030
# - 2040
- 2050
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#countries
countries: ['AL', 'AT', 'BA', 'BE', 'BG', 'CH', 'CZ', 'DE', 'DK', 'EE', 'ES', 'FI', 'FR', 'GB', 'GR', 'HR', 'HU', 'IE', 'IT', 'LT', 'LU', 'LV', 'ME', 'MK', 'NL', 'NO', 'PL', 'PT', 'RO', 'RS', 'SE', 'SI', 'SK']
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#snapshots
snapshots:
start: "2013-01-01"
end: "2014-01-01"
inclusive: 'left'
resolution: false
segmentation: false
#representative: false
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#enable
enable:
retrieve: auto
prepare_links_p_nom: false
retrieve_databundle: true
retrieve_sector_databundle: true
retrieve_cost_data: true
build_cutout: false
retrieve_irena: false
retrieve_cutout: true
build_natura_raster: false
retrieve_natura_raster: true
custom_busmap: false
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#co2-budget
co2_budget:
2020: 0.701
2025: 0.524
2030: 0.297
2035: 0.150
2040: 0.071
2045: 0.032
2050: 0.000
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#electricity
electricity:
voltages: [220., 300., 380., 500., 750.]
gaslimit_enable: false
gaslimit: false
co2limit_enable: false
co2limit: 7.75e+7
co2base: 1.487e+9
agg_p_nom_limits: data/agg_p_nom_minmax.csv
operational_reserve:
activate: false
epsilon_load: 0.02
epsilon_vres: 0.02
contingency: 4000
max_hours:
battery: 6
H2: 168
extendable_carriers:
Generator: [solar, onwind, offwind-ac, offwind-dc, OCGT]
StorageUnit: [] # battery, H2
Store: [battery, H2]
Link: [] # H2 pipeline
powerplants_filter: (DateOut >= 2023 or DateOut != DateOut) and not (Country == 'Germany' and Fueltype == 'Nuclear')
custom_powerplants: false
everywhere_powerplants: [nuclear, oil, OCGT, CCGT, coal, lignite, geothermal, biomass]
conventional_carriers: [nuclear, oil, OCGT, CCGT, coal, lignite, geothermal, biomass]
renewable_carriers: [solar, onwind, offwind-ac, offwind-dc, hydro]
estimate_renewable_capacities:
enable: true
from_opsd: true
year: 2020
expansion_limit: false
technology_mapping:
Offshore: [offwind-ac, offwind-dc]
Onshore: [onwind]
PV: [solar]
autarky:
enable: false
by_country: false
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#atlite
atlite:
default_cutout: europe-2013-era5
nprocesses: 4
show_progress: false
cutouts:
# use 'base' to determine geographical bounds and time span from config
# base:
# module: era5
europe-2013-era5:
module: era5 # in priority order
x: [-12., 42.]
y: [33., 72]
dx: 0.3
dy: 0.3
time: ['2013', '2013']
europe-2013-sarah:
module: [sarah, era5] # in priority order
x: [-12., 42.]
y: [33., 65]
dx: 0.2
dy: 0.2
time: ['2013', '2013']
sarah_interpolate: false
sarah_dir:
features: [influx, temperature]
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#renewable
renewable:
onwind:
cutout: europe-2013-era5
resource:
method: wind
turbine: Vestas_V112_3MW
add_cutout_windspeed: true
capacity_per_sqkm: 3
# correction_factor: 0.93
corine:
grid_codes: [12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 31, 32]
distance: 1000
distance_grid_codes: [1, 2, 3, 4, 5, 6]
luisa: false
# grid_codes: [1111, 1121, 1122, 1123, 1130, 1210, 1221, 1222, 1230, 1241, 1242]
# distance: 1000
# distance_grid_codes: [1111, 1121, 1122, 1123, 1130, 1210, 1221, 1222, 1230, 1241, 1242]
natura: true
excluder_resolution: 100
clip_p_max_pu: 1.e-2
offwind-ac:
cutout: europe-2013-era5
resource:
method: wind
turbine: NREL_ReferenceTurbine_2020ATB_5.5MW
add_cutout_windspeed: true
capacity_per_sqkm: 2
correction_factor: 0.8855
corine: [44, 255]
luisa: false # [0, 5230]
natura: true
ship_threshold: 400
max_depth: 50
max_shore_distance: 30000
excluder_resolution: 200
clip_p_max_pu: 1.e-2
offwind-dc:
cutout: europe-2013-era5
resource:
method: wind
turbine: NREL_ReferenceTurbine_2020ATB_5.5MW
add_cutout_windspeed: true
capacity_per_sqkm: 2
correction_factor: 0.8855
corine: [44, 255]
luisa: false # [0, 5230]
natura: true
ship_threshold: 400
max_depth: 50
min_shore_distance: 30000
excluder_resolution: 200
clip_p_max_pu: 1.e-2
solar:
cutout: europe-2013-sarah
resource:
method: pv
panel: CSi
orientation:
slope: 35.
azimuth: 180.
capacity_per_sqkm: 5.1
# correction_factor: 0.854337
corine: [1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 26, 31, 32]
luisa: false # [1111, 1121, 1122, 1123, 1130, 1210, 1221, 1222, 1230, 1241, 1242, 1310, 1320, 1330, 1410, 1421, 1422, 2110, 2120, 2130, 2210, 2220, 2230, 2310, 2410, 2420, 3210, 3320, 3330]
natura: true
excluder_resolution: 100
clip_p_max_pu: 1.e-2
hydro:
cutout: europe-2013-era5
carriers: [ror, PHS, hydro]
PHS_max_hours: 6
hydro_max_hours: "energy_capacity_totals_by_country" # one of energy_capacity_totals_by_country, estimate_by_large_installations or a float
flatten_dispatch: false
flatten_dispatch_buffer: 0.2
clip_min_inflow: 1.0
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#conventional
conventional:
unit_commitment: false
dynamic_fuel_price: false
nuclear:
p_max_pu: "data/nuclear_p_max_pu.csv" # float of file name
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#lines
lines:
types:
220.: "Al/St 240/40 2-bundle 220.0"
300.: "Al/St 240/40 3-bundle 300.0"
380.: "Al/St 240/40 4-bundle 380.0"
500.: "Al/St 240/40 4-bundle 380.0"
750.: "Al/St 560/50 4-bundle 750.0"
s_max_pu: 0.7
s_nom_max: .inf
max_extension: 20000 #MW
length_factor: 1.25
reconnect_crimea: true
under_construction: 'zero' # 'zero': set capacity to zero, 'remove': remove, 'keep': with full capacity
dynamic_line_rating:
activate: false
cutout: europe-2013-era5
correction_factor: 0.95
max_voltage_difference: false
max_line_rating: false
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#links
links:
p_max_pu: 1.0
p_nom_max: .inf
max_extension: 30000 #MW
include_tyndp: true
under_construction: 'zero' # 'zero': set capacity to zero, 'remove': remove, 'keep': with full capacity
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#transformers
transformers:
x: 0.1
s_nom: 2000.
type: ''
# docs-load in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#load
load:
power_statistics: true
interpolate_limit: 3
time_shift_for_large_gaps: 1w
manual_adjustments: true # false
scaling_factor: 1.0
# docs
# TODO: PyPSA-Eur merge issue in prepare_sector_network.py
# regulate what components with which carriers are kept from PyPSA-Eur;
# some technologies are removed because they are implemented differently
# (e.g. battery or H2 storage) or have different year-dependent costs
# in PyPSA-Eur-Sec
pypsa_eur:
Bus:
- AC
Link:
- DC
Generator:
- onwind
- offwind-ac
- offwind-dc
- solar
- ror
- nuclear
StorageUnit:
- PHS
- hydro
Store: []
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#energy
energy:
energy_totals_year: 2011
base_emissions_year: 1990
eurostat_report_year: 2016
emissions: CO2
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#biomass
biomass:
year: 2030
scenario: ENS_Med
classes:
solid biomass:
- Agricultural waste
- Fuelwood residues
- Secondary Forestry residues - woodchips
- Sawdust
- Residues from landscape care
- Municipal waste
not included:
- Sugar from sugar beet
- Rape seed
- "Sunflower, soya seed "
- Bioethanol barley, wheat, grain maize, oats, other cereals and rye
- Miscanthus, switchgrass, RCG
- Willow
- Poplar
- FuelwoodRW
- C&P_RW
biogas:
- Manure solid, liquid
- Sludge
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#solar-thermal
solar_thermal:
clearsky_model: simple # should be "simple" or "enhanced"?
orientation:
slope: 45.
azimuth: 180.
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#existing-capacities
existing_capacities:
grouping_years_power: [1980, 1985, 1990, 1995, 2000, 2005, 2010, 2015, 2020, 2025, 2030]
grouping_years_heat: [1980, 1985, 1990, 1995, 2000, 2005, 2010, 2015, 2019] # these should not extend 2020
threshold_capacity: 10
default_heating_lifetime: 20
conventional_carriers:
- lignite
- coal
- oil
- uranium
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#sector
sector:
district_heating:
potential: 0.6
progress:
2020: 0.0
2025: 0.15
2030: 0.3
2035: 0.45
2040: 0.6
2045: 0.8
2050: 1.0
district_heating_loss: 0.15
cluster_heat_buses: true
bev_dsm_restriction_value: 0.75
bev_dsm_restriction_time: 7
transport_heating_deadband_upper: 20.
transport_heating_deadband_lower: 15.
ICE_lower_degree_factor: 0.375
ICE_upper_degree_factor: 1.6
EV_lower_degree_factor: 0.98
EV_upper_degree_factor: 0.63
bev_dsm: true
bev_availability: 0.5
bev_energy: 0.05
bev_charge_efficiency: 0.9
bev_plug_to_wheel_efficiency: 0.2
bev_charge_rate: 0.011
bev_avail_max: 0.95
bev_avail_mean: 0.8
v2g: true
land_transport_fuel_cell_share:
2020: 0
2025: 0
2030: 0
2035: 0
2040: 0
2045: 0
2050: 0
land_transport_electric_share:
2020: 0
2025: 0.15
2030: 0.3
2035: 0.45
2040: 0.7
2045: 0.85
2050: 1
land_transport_ice_share:
2020: 1
2025: 0.85
2030: 0.7
2035: 0.55
2040: 0.3
2045: 0.15
2050: 0
transport_fuel_cell_efficiency: 0.5
transport_internal_combustion_efficiency: 0.3
agriculture_machinery_electric_share: 0
agriculture_machinery_oil_share: 1
agriculture_machinery_fuel_efficiency: 0.7
agriculture_machinery_electric_efficiency: 0.3
MWh_MeOH_per_MWh_H2: 0.8787
MWh_MeOH_per_tCO2: 4.0321
MWh_MeOH_per_MWh_e: 3.6907
shipping_hydrogen_liquefaction: false
shipping_hydrogen_share:
2020: 0
2025: 0
2030: 0
2035: 0
2040: 0
2045: 0
2050: 0
shipping_methanol_share:
2020: 0
2025: 0.15
2030: 0.3
2035: 0.5
2040: 0.7
2045: 0.85
2050: 1
shipping_oil_share:
2020: 1
2025: 0.85
2030: 0.7
2035: 0.5
2040: 0.3
2045: 0.15
2050: 0
shipping_methanol_efficiency: 0.46
shipping_oil_efficiency: 0.40
aviation_demand_factor: 1.
HVC_demand_factor: 1.
time_dep_hp_cop: true
heat_pump_sink_T: 55.
reduce_space_heat_exogenously: true
reduce_space_heat_exogenously_factor:
2020: 0.10 # this results in a space heat demand reduction of 10%
2025: 0.09 # first heat demand increases compared to 2020 because of larger floor area per capita
2030: 0.09
2035: 0.11
2040: 0.16
2045: 0.21
2050: 0.29
retrofitting:
retro_endogen: false
cost_factor: 1.0
interest_rate: 0.04
annualise_cost: true
tax_weighting: false
construction_index: true
tes: true
tes_tau:
decentral: 3
central: 180
boilers: true
resistive_heaters: true
oil_boilers: false
biomass_boiler: true
chp: true
micro_chp: false
solar_thermal: true
solar_cf_correction: 0.788457 # = >>> 1/1.2683
marginal_cost_storage: 0. #1e-4
methanation: true
coal_cc: false
dac: true
co2_vent: false
central_heat_vent: false
allam_cycle: false
hydrogen_fuel_cell: true
hydrogen_turbine: false
SMR: true
SMR_cc: true
regional_methanol_demand: false
regional_oil_demand: false
regional_co2_sequestration_potential:
enable: false
attribute: 'conservative estimate Mt'
include_onshore: false
min_size: 3
max_size: 25
years_of_storage: 25
co2_sequestration_potential: 200
co2_sequestration_cost: 10
co2_sequestration_lifetime: 50
co2_spatial: false
co2network: false
co2_network_cost_factor: 1
cc_fraction: 0.9
hydrogen_underground_storage: true
hydrogen_underground_storage_locations:
# - onshore # more than 50 km from sea
- nearshore # within 50 km of sea
# - offshore
ammonia: false
min_part_load_fischer_tropsch: 0.7
min_part_load_methanolisation: 0.3
min_part_load_methanation: 0.3
use_fischer_tropsch_waste_heat: true
use_haber_bosch_waste_heat: true
use_methanolisation_waste_heat: true
use_methanation_waste_heat: true
use_fuel_cell_waste_heat: true
use_electrolysis_waste_heat: true
electricity_distribution_grid: true
electricity_distribution_grid_cost_factor: 1.0
electricity_grid_connection: true
transmission_efficiency:
DC:
efficiency_static: 0.98
efficiency_per_1000km: 0.977
H2 pipeline:
efficiency_per_1000km: 1 # 0.979
compression_per_1000km: 0.019
gas pipeline:
efficiency_per_1000km: 1 #0.977
compression_per_1000km: 0.01
H2_network: true
gas_network: false
H2_retrofit: false
H2_retrofit_capacity_per_CH4: 0.6
gas_network_connectivity_upgrade: 1
gas_distribution_grid: true
gas_distribution_grid_cost_factor: 1.0
biomass_spatial: false
biomass_transport: false
biogas_upgrading_cc: false
conventional_generation:
OCGT: gas
biomass_to_liquid: false
biosng: false
limit_max_growth:
enable: false
# allowing 30% larger than max historic growth
factor: 1.3
max_growth: # unit GW
onwind: 16 # onshore max grow so far 16 GW in Europe https://www.iea.org/reports/renewables-2020/wind
solar: 28 # solar max grow so far 28 GW in Europe https://www.iea.org/reports/renewables-2020/solar-pv
offwind-ac: 35 # offshore max grow so far 3.5 GW in Europe https://windeurope.org/about-wind/statistics/offshore/european-offshore-wind-industry-key-trends-statistics-2019/
offwind-dc: 35
max_relative_growth:
onwind: 3
solar: 3
offwind-ac: 3
offwind-dc: 3
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#industry
industry:
St_primary_fraction:
2020: 0.6
2025: 0.55
2030: 0.5
2035: 0.45
2040: 0.4
2045: 0.35
2050: 0.3
DRI_fraction:
2020: 0
2025: 0
2030: 0.05
2035: 0.2
2040: 0.4
2045: 0.7
2050: 1
H2_DRI: 1.7
elec_DRI: 0.322
Al_primary_fraction:
2020: 0.4
2025: 0.375
2030: 0.35
2035: 0.325
2040: 0.3
2045: 0.25
2050: 0.2
MWh_NH3_per_tNH3: 5.166
MWh_CH4_per_tNH3_SMR: 10.8
MWh_elec_per_tNH3_SMR: 0.7
MWh_H2_per_tNH3_electrolysis: 5.93
MWh_elec_per_tNH3_electrolysis: 0.2473
MWh_NH3_per_MWh_H2_cracker: 1.46 # https://github.com/euronion/trace/blob/44a5ff8401762edbef80eff9cfe5a47c8d3c8be4/data/efficiencies.csv
NH3_process_emissions: 24.5
petrochemical_process_emissions: 25.5
#HVC primary/recycling based on values used in Neumann et al https://doi.org/10.1016/j.joule.2023.06.016, linearly interpolated between 2020 and 2050
#2020 recycling rates based on Agora https://static.agora-energiewende.de/fileadmin/Projekte/2021/2021_02_EU_CEAP/A-EW_254_Mobilising-circular-economy_study_WEB.pdf
#fractions refer to the total primary HVC production in 2020
#assumes 6.7 Mtplastics produced from recycling in 2020
HVC_primary_fraction:
2020: 1.0
2025: 0.9
2030: 0.8
2035: 0.7
2040: 0.6
2045: 0.5
2050: 0.4
HVC_mechanical_recycling_fraction:
2020: 0.12
2025: 0.15
2030: 0.18
2035: 0.21
2040: 0.24
2045: 0.27
2050: 0.30
HVC_chemical_recycling_fraction:
2020: 0.0
2025: 0.0
2030: 0.04
2035: 0.08
2040: 0.12
2045: 0.16
2050: 0.20
HVC_production_today: 52.
MWh_elec_per_tHVC_mechanical_recycling: 0.547
MWh_elec_per_tHVC_chemical_recycling: 6.9
chlorine_production_today: 9.58
MWh_elec_per_tCl: 3.6
MWh_H2_per_tCl: -0.9372
methanol_production_today: 1.5
MWh_elec_per_tMeOH: 0.167
MWh_CH4_per_tMeOH: 10.25
hotmaps_locate_missing: false
reference_year: 2015
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#costs
costs:
year: 2030
version: v0.7.0
rooftop_share: 0.14 # based on the potentials, assuming (0.1 kW/m2 and 10 m2/person)
social_discountrate: 0.02
fill_values:
FOM: 0
VOM: 0
efficiency: 1
fuel: 0
investment: 0
lifetime: 25
"CO2 intensity": 0
"discount rate": 0.07
# Marginal and capital costs can be overwritten
# capital_cost:
# onwind: 500
marginal_cost:
solar: 0.01
onwind: 0.015
offwind: 0.015
hydro: 0.
H2: 0.
electrolysis: 0.
fuel cell: 0.
battery: 0.
battery inverter: 0.
emission_prices:
enable: false
co2: 0.
co2_monthly_prices: false
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#clustering
clustering:
focus_weights: false
simplify_network:
to_substations: false
algorithm: kmeans # choose from: [hac, kmeans]
feature: solar+onwind-time
exclude_carriers: []
remove_stubs: true
remove_stubs_across_borders: true
cluster_network:
algorithm: kmeans
feature: solar+onwind-time
exclude_carriers: []
consider_efficiency_classes: false
aggregation_strategies:
generators:
committable: any
ramp_limit_up: max
ramp_limit_down: max
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#solving
solving:
#tmpdir: "path/to/tmp"
options:
clip_p_max_pu: 1.e-2
load_shedding: false
noisy_costs: true
skip_iterations: true
rolling_horizon: false
seed: 123
custom_extra_functionality: "../data/custom_extra_functionality.py"
# io_api: "direct" # Increases performance but only supported for the highs and gurobi solvers
# options that go into the optimize function
track_iterations: false
min_iterations: 4
max_iterations: 6
transmission_losses: 2
linearized_unit_commitment: true
horizon: 365
constraints:
CCL: false
EQ: false
BAU: false
SAFE: false
solver:
name: gurobi
options: gurobi-default
solver_options:
highs-default:
# refer to https://ergo-code.github.io/HiGHS/options/definitions.html#solver
threads: 4
solver: "ipm"
run_crossover: "off"
small_matrix_value: 1e-6
large_matrix_value: 1e9
primal_feasibility_tolerance: 1e-5
dual_feasibility_tolerance: 1e-5
ipm_optimality_tolerance: 1e-4
parallel: "on"
random_seed: 123
gurobi-default:
threads: 4
method: 2 # barrier
crossover: 0
BarConvTol: 1.e-6
Seed: 123
AggFill: 0
PreDual: 0
GURO_PAR_BARDENSETHRESH: 200
gurobi-numeric-focus:
name: gurobi
NumericFocus: 3 # Favour numeric stability over speed
method: 2 # barrier
crossover: 0 # do not use crossover
BarHomogeneous: 1 # Use homogeneous barrier if standard does not converge
BarConvTol: 1.e-5
FeasibilityTol: 1.e-4
OptimalityTol: 1.e-4
ObjScale: -0.5
threads: 8
Seed: 123
gurobi-fallback: # Use gurobi defaults
name: gurobi
crossover: 0
method: 2 # barrier
BarHomogeneous: 1 # Use homogeneous barrier if standard does not converge
BarConvTol: 1.e-5
FeasibilityTol: 1.e-5
OptimalityTol: 1.e-5
Seed: 123
threads: 8
cplex-default:
threads: 4
lpmethod: 4 # barrier
solutiontype: 2 # non basic solution, ie no crossover
barrier.convergetol: 1.e-5
feasopt.tolerance: 1.e-6
copt-default:
Threads: 8
LpMethod: 2
Crossover: 0
cbc-default: {} # Used in CI
glpk-default: {} # Used in CI
mem: 30000 #memory in MB; 20 GB enough for 50+B+I+H2; 100 GB for 181+B+I+H2
walltime: "12:00:00"
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#plotting
plotting:
map:
boundaries: [-11, 30, 34, 71]
color_geomap:
ocean: white
land: white
projection:
name: "EqualEarth"
# See https://scitools.org.uk/cartopy/docs/latest/reference/projections.html for alternatives, for example:
# name: "LambertConformal"
# central_longitude: 10.
# central_latitude: 50.
# standard_parallels: [35, 65]
eu_node_location:
x: -5.5
y: 46.
costs_max: 1000
costs_threshold: 1
energy_max: 20000
energy_min: -20000
energy_threshold: 50.
nice_names:
OCGT: "Open-Cycle Gas"
CCGT: "Combined-Cycle Gas"
offwind-ac: "Offshore Wind (AC)"
offwind-dc: "Offshore Wind (DC)"
onwind: "Onshore Wind"
solar: "Solar"
PHS: "Pumped Hydro Storage"
hydro: "Reservoir & Dam"
battery: "Battery Storage"
H2: "Hydrogen Storage"
lines: "Transmission Lines"
ror: "Run of River"
load: "Load Shedding"
ac: "AC"
dc: "DC"
tech_colors:
# wind
onwind: "#235ebc"
onshore wind: "#235ebc"
offwind: "#6895dd"
offshore wind: "#6895dd"
offwind-ac: "#6895dd"
offshore wind (AC): "#6895dd"
offshore wind ac: "#6895dd"
offwind-dc: "#74c6f2"
offshore wind (DC): "#74c6f2"
offshore wind dc: "#74c6f2"
# water
hydro: '#298c81'
hydro reservoir: '#298c81'
ror: '#3dbfb0'
run of river: '#3dbfb0'
hydroelectricity: '#298c81'
PHS: '#51dbcc'
hydro+PHS: "#08ad97"
# solar
solar: "#f9d002"
solar PV: "#f9d002"
solar thermal: '#ffbf2b'
residential rural solar thermal: '#f1c069'
services rural solar thermal: '#eabf61'
residential urban decentral solar thermal: '#e5bc5a'
services urban decentral solar thermal: '#dfb953'
urban central solar thermal: '#d7b24c'
solar rooftop: '#ffea80'
# gas
OCGT: '#e0986c'
OCGT marginal: '#e0986c'
OCGT-heat: '#e0986c'
gas boiler: '#db6a25'
gas boilers: '#db6a25'
gas boiler marginal: '#db6a25'
residential rural gas boiler: '#d4722e'
residential urban decentral gas boiler: '#cb7a36'
services rural gas boiler: '#c4813f'
services urban decentral gas boiler: '#ba8947'
urban central gas boiler: '#b0904f'
gas: '#e05b09'
fossil gas: '#e05b09'
natural gas: '#e05b09'
biogas to gas: '#e36311'
biogas to gas CC: '#e51245'
CCGT: '#a85522'
CCGT marginal: '#a85522'
allam: '#B98F76'
gas for industry co2 to atmosphere: '#692e0a'
gas for industry co2 to stored: '#8a3400'
gas for industry: '#853403'
gas for industry CC: '#692e0a'
gas pipeline: '#ebbca0'
gas pipeline new: '#a87c62'
# oil
oil: '#c9c9c9'
imported oil: '#a3a3a3'
oil boiler: '#adadad'
residential rural oil boiler: '#a9a9a9'
services rural oil boiler: '#a5a5a5'
residential urban decentral oil boiler: '#a1a1a1'
urban central oil boiler: '#9d9d9d'
services urban decentral oil boiler: '#999999'
agriculture machinery oil: '#949494'
shipping oil: "#808080"
land transport oil: '#afafaf'
# nuclear
Nuclear: '#ff8c00'
Nuclear marginal: '#ff8c00'
nuclear: '#ff8c00'
uranium: '#ff8c00'
# coal
Coal: '#545454'
coal: '#545454'
Coal marginal: '#545454'
coal for industry: '#343434'
solid: '#545454'
Lignite: '#826837'
lignite: '#826837'
Lignite marginal: '#826837'
# biomass
biogas: '#e3d37d'
biomass: '#baa741'
solid biomass: '#baa741'
solid biomass transport: '#baa741'
solid biomass for industry: '#7a6d26'
solid biomass for industry CC: '#47411c'
solid biomass for industry co2 from atmosphere: '#736412'
solid biomass for industry co2 to stored: '#47411c'
urban central solid biomass CHP: '#9d9042'
urban central solid biomass CHP CC: '#6c5d28'
biomass boiler: '#8A9A5B'
residential rural biomass boiler: '#a1a066'
residential urban decentral biomass boiler: '#b0b87b'
services rural biomass boiler: '#c6cf98'
services urban decentral biomass boiler: '#dde5b5'
biomass to liquid: '#32CD32'
BioSNG: '#123456'
# power transmission
lines: '#6c9459'
transmission lines: '#6c9459'
electricity distribution grid: '#97ad8c'
low voltage: '#97ad8c'
# electricity demand
Electric load: '#110d63'
electric demand: '#110d63'
electricity: '#110d63'
industry electricity: '#2d2a66'
industry new electricity: '#2d2a66'
agriculture electricity: '#494778'
# battery + EVs
battery: '#ace37f'
battery storage: '#ace37f'
battery charger: '#88a75b'
battery discharger: '#5d4e29'
home battery: '#80c944'
home battery storage: '#80c944'
home battery charger: '#5e8032'
home battery discharger: '#3c5221'
BEV charger: '#baf238'
V2G: '#e5ffa8'
land transport EV: '#baf238'
Li ion: '#baf238'
# hot water storage
water tanks: '#e69487'
residential rural water tanks: '#f7b7a3'
services rural water tanks: '#f3afa3'
residential urban decentral water tanks: '#f2b2a3'
services urban decentral water tanks: '#f1b4a4'
urban central water tanks: '#e9977d'
hot water storage: '#e69487'
hot water charging: '#e8998b'
urban central water tanks charger: '#b57a67'
residential rural water tanks charger: '#b4887c'
residential urban decentral water tanks charger: '#b39995'
services rural water tanks charger: '#b3abb0'
services urban decentral water tanks charger: '#b3becc'
hot water discharging: '#e99c8e'
urban central water tanks discharger: '#b9816e'
residential rural water tanks discharger: '#ba9685'
residential urban decentral water tanks discharger: '#baac9e'
services rural water tanks discharger: '#bbc2b8'
services urban decentral water tanks discharger: '#bdd8d3'
# heat demand
Heat load: '#cc1f1f'
heat: '#cc1f1f'
heat vent: '#aa3344'
heat demand: '#cc1f1f'
rural heat: '#ff5c5c'
residential rural heat: '#ff7c7c'
services rural heat: '#ff9c9c'
central heat: '#cc1f1f'
urban central heat: '#d15959'
urban central heat vent: '#a74747'
decentral heat: '#750606'
residential urban decentral heat: '#a33c3c'
services urban decentral heat: '#cc1f1f'
low-temperature heat for industry: '#8f2727'
process heat: '#ff0000'
agriculture heat: '#d9a5a5'
# heat supply
heat pumps: '#2fb537'
heat pump: '#2fb537'
air heat pump: '#36eb41'
residential urban decentral air heat pump: '#48f74f'
services urban decentral air heat pump: '#5af95d'
urban central air heat pump: '#6cfb6b'
ground heat pump: '#2fb537'
residential rural ground heat pump: '#48f74f'
services rural ground heat pump: '#5af95d'
Ambient: '#98eb9d'
CHP: '#8a5751'
urban central gas CHP: '#8d5e56'
CHP CC: '#634643'
urban central gas CHP CC: '#6e4e4c'
CHP heat: '#8a5751'
CHP electric: '#8a5751'
district heating: '#e8beac'
resistive heater: '#d8f9b8'
residential rural resistive heater: '#bef5b5'
residential urban decentral resistive heater: '#b2f1a9'
services rural resistive heater: '#a5ed9d'
services urban decentral resistive heater: '#98e991'
urban central resistive heater: '#8cdf85'
retrofitting: '#8487e8'
building retrofitting: '#8487e8'
# hydrogen
H2 for industry: "#f073da"
H2 for shipping: "#ebaee0"
H2: '#bf13a0'
hydrogen: '#bf13a0'
retrofitted H2 boiler: '#e5a0d9'
SMR: '#870c71'
SMR CC: '#4f1745'
H2 liquefaction: '#d647bd'
hydrogen storage: '#bf13a0'
H2 Store: '#bf13a0'
H2 storage: '#bf13a0'
land transport fuel cell: '#6b3161'
H2 pipeline: '#f081dc'
H2 pipeline retrofitted: '#ba99b5'
H2 Fuel Cell: '#c251ae'
H2 fuel cell: '#c251ae'
H2 turbine: '#991f83'
H2 Electrolysis: '#ff29d9'
H2 electrolysis: '#ff29d9'
# ammonia
NH3: '#46caf0'
ammonia: '#46caf0'
ammonia store: '#00ace0'
ammonia cracker: '#87d0e6'
Haber-Bosch: '#076987'
# syngas
Sabatier: '#9850ad'
methanation: '#c44ce6'
methane: '#c44ce6'
# synfuels
Fischer-Tropsch: '#25c49a'
liquid: '#25c49a'
kerosene for aviation: '#a1ffe6'
naphtha for industry: '#57ebc4'
methanolisation: '#83d6d5'
methanol: '#468c8b'
shipping methanol: '#468c8b'
# co2
CC: '#f29dae'
CCS: '#f29dae'
CO2 sequestration: '#f29dae'
DAC: '#ff5270'
co2 stored: '#f2385a'
co2 sequestered: '#f2682f'
co2: '#f29dae'
co2 vent: '#ffd4dc'
CO2 pipeline: '#f5627f'
# emissions
process emissions CC: '#000000'
process emissions: '#222222'
process emissions to stored: '#444444'
process emissions to atmosphere: '#888888'
oil emissions: '#aaaaaa'
shipping oil emissions: "#555555"
shipping methanol emissions: '#666666'
land transport oil emissions: '#777777'
agriculture machinery oil emissions: '#333333'
# other
shipping: '#03a2ff'
power-to-heat: '#2fb537'
power-to-gas: '#c44ce6'
power-to-H2: '#ff29d9'
power-to-liquid: '#25c49a'
gas-to-power/heat: '#ee8340'
waste: '#e3d37d'
other: '#000000'
geothermal: '#ba91b1'
AC: "#70af1d"
AC-AC: "#70af1d"
AC line: "#70af1d"
links: "#8a1caf"
HVDC links: "#8a1caf"
DC: "#8a1caf"
DC-DC: "#8a1caf"
DC link: "#8a1caf"
load: "#dd2e23"