logging_level: INFO
results_dir: 'results/'
summary_dir: results
run: '190508-test_fossil'
scenario:
sectors: [E] # ,E+EV,E+BEV,E+BEV+V2G] # [ E+EV, E+BEV, E+BEV+V2G ]
simpl: ['']
lv: [1.0]# or opt
clusters: [128] #[90, 128, 181] #[45, 64, 90, 128, 181, 256] #, 362] # (2**np.r_[5.5:9:.5]).astype(int) minimum is 37
opts: [''] #for pypsa-eur
sector_opts: [Co2L0-3H-T-H-B-I,Co2L0p1-3H-T-H-B-I,Co2L0p25-3H-T-H-B-I,Co2L0p50-3H-T-H-B-I]#[Co2L0-3H-T-H-B-I-onwind0-solar3,Co2L0-3H-T-H-B-I-onwind0p125-solar3,Co2L0-3H-T-H-B-I-onwind0p25-solar3,Co2L0-3H-T-H-B-I-onwind0p50-solar3,Co2L0-3H-T-H-B-I-solar3]#,Co2L0-3H-T-H-B-I-onwind0p25-solar3]#,Co2L0p05-3H-T-H-B-I,Co2L0p10-3H-T-H-B-I,Co2L0p20-3H-T-H-B-I,Co2L0p30-3H-T-H-B-I,Co2L0p50-3H-T-H-B-I]#[Co2L-3H-T-H,Co2L0p10-3H-T-H,Co2L0-3H-T-H,Co2L0p20-3H-T-H] #Co2L-3H-T-H,Co2L0p10-3H-T-H,Co2L0p20-3H-T-HCo2L-3H-T-H,Co2L0p10-3H-T-H,Co2L0p30-3H-T-H,Co2L0p50-3H-T-H] #Co2L-3H,Co2L-3H-T,, LC-FL, LC-T, Ep-T, Co2L-T]
# Co2L will give default (5%); Co2L0p25 will give 25% CO2 emissions; Co2Lm0p05 will give 5% negative emissions
snapshots:
# arguments to pd.date_range
start: "2013-01-01"
end: "2014-01-01"
closed: 'left' # end is not inclusive
electricity:
voltages: [220., 300., 380.]
extendable_carriers:
Generator: [] # [OCGT]
StorageUnit: [] # [battery, H2, CAES]
max_hours:
battery: 6
H2: 168
conventional_carriers: [] # nuclear, oil, OCGT, CCGT, coal, lignite, geothermal, biomass]
atlite:
cutout_dir: '../pypsa-eur/cutouts'
renewable:
onwind:
cutout: europe-2013-era5
biomass:
year: 2030
scenario: "Med"
sector:
'central' : True
'central_fraction' : 0.6
'dsm_restriction_value' : 0.75 #Set to 0 for no restriction on BEV DSM
'dsm_restriction_time' : 7 #Time at which SOC of BEV has to be dsm_restriction_value
'transport_heating_deadband_upper' : 20.
'transport_heating_deadband_lower' : 15.
'ICE_lower_degree_factor' : 0.375 #in per cent increase in fuel consumption per degree above deadband
'ICE_upper_degree_factor' : 1.6
'EV_lower_degree_factor' : 0.98
'EV_upper_degree_factor' : 0.63
'district_heating_loss' : 0.1
'bev' : True #turns on EV battery
'bev_availability' : 0.5 #How many cars do smart charging
'v2g' : True #allows feed-in to grid from EV battery
'transport_fuel_cell_share' : 0. #0 means all EVs, 1 means all FCs
'time_dep_hp_cop' : True
'retrofitting' : False
'retroI-fraction' : 0.25
'retroI-fraction' : 0.55
'retrofitting-cost_factor' : 1.0
'tes' : True
'tes_tau' : 3.
'boilers' : True
'chp' : True
'chp_parameters':
'eta_elec' : 0.468 #electrical efficiency with no heat output
'c_v' : 0.15 #loss of fuel for each addition of heat
'c_m' : 0.75 #backpressure ratio
'p_nom_ratio' : 1. #ratio of max heat output to max electrical output
'solar_thermal' : True
'solar_cf_correction': 0.788457 # = >>> 1/1.2683
'marginal_cost_storage' : 0. #1e-4
'methanation' : True
'helmeth' : True
'dac' : True
'ccs_fraction' : 0.9
costs:
year: 2030
# From a Lion Hirth paper, also reflects average of Noothout et al 2016
discountrate: 0.07
# [EUR/USD] ECB: https://www.ecb.europa.eu/stats/exchange/eurofxref/html/eurofxref-graph-usd.en.html # noqa: E501
USD2013_to_EUR2013: 0.7532
# Marginal and capital costs can be overwritten
# capital_cost:
# Wind: Bla
marginal_cost: #
solar: 0.01
onwind: 0.015
offwind: 0.015
hydro: 0.
H2: 0.
battery: 0.
emission_prices: # only used with the option Ep (emission prices)
co2: 0.
solving:
options:
formulation: kirchhoff
clip_p_max_pu: 1.e-2
load_shedding: false
noisy_costs: true
min_iterations: 1
max_iterations: 1
# max_iterations: 1
# nhours: 1
solver:
name: gurobi
threads: 4
method: 2 # barrier
crossover: 0
BarConvTol: 1.e-5
FeasibilityTol: 1.e-6
# solver:
# name: cplex
# threads: 4
# lpmethod: 4 # barrier
# solutiontype: 2 # non basic solution, ie no crossover
# barrier.convergetol: 1.e-5
# feasopt.tolerance: 1.e-6
plotting:
map:
figsize: [7, 7]
boundaries: [-10.2, 29, 35, 72]
p_nom:
bus_size_factor: 5.e+4
linewidth_factor: 3.e+3 # 1.e+3 #3.e+3
costs_max: 1200
costs_threshold: 1
energy_max: 15000.
energy_min: -15000.
energy_threshold: 50.
vre_techs: ["onwind", "offwind-ac", "offwind-dc", "solar", "ror"]
renewable_storage_techs: ["PHS","hydro"]
conv_techs: ["OCGT", "CCGT", "Nuclear", "Coal"]
storage_techs: ["hydro+PHS", "battery", "H2"]
# store_techs: ["Li ion", "water tanks"]
load_carriers: ["AC load"] #, "heat load", "Li ion load"]
AC_carriers: ["AC line", "AC transformer"]
link_carriers: ["DC line", "Converter AC-DC"]
heat_links: ["heat pump", "resistive heater", "CHP heat", "CHP electric",
"gas boiler", "central heat pump", "central resistive heater", "central CHP heat",
"central CHP electric", "central gas boiler"]
heat_generators: ["gas boiler", "central gas boiler", "solar thermal collector", "central solar thermal collector"]
tech_colors:
"onwind" : "b"
"onshore wind" : "b"
'offwind' : "c"
'offshore wind' : "c"
'offwind-ac' : "c"
'offshore wind (AC)' : "c"
'offwind-dc' : "#009999"
'offshore wind (DC)' : "#009999"
"hydro" : "#3B5323"
"hydro reservoir" : "#3B5323"
"ror" : "#78AB46"
"run of river" : "#78AB46"
'hydroelectricity' : '#006400'
'solar' : "y"
'solar PV' : "y"
'solar thermal' : 'coral'
"OCGT" : "wheat"
"OCGT marginal" : "sandybrown"
"OCGT-heat" : "orange"
"gas boiler" : "orange"
"gas boilers" : "orange"
"gas boiler marginal" : "orange"
"gas-to-power/heat" : "orange"
"gas" : "brown"
"natural gas" : "brown"
"lines" : "k"
"transmission lines" : "k"
"H2" : "m"
"hydrogen storage" : "m"
"battery" : "slategray"
"battery storage" : "slategray"
"Nuclear" : "r"
"Nuclear marginal" : "r"
"Coal" : "k"
"Coal marginal" : "k"
"Lignite" : "grey"
"Lignite marginal" : "grey"
"CCGT" : "orange"
"CCGT marginal" : "orange"
"heat pumps" : "#76EE00"
"heat pump" : "#76EE00"
"air heat pump" : "#76EE00"
"ground heat pump" : "#40AA00"
"power-to-heat" : "#40AA00"
"resistive heater" : "pink"
"Sabatier" : "#FF1493"
"methanation" : "#FF1493"
"power-to-gas" : "#FF1493"
"power-to-liquid" : "#FFAAE9"
"helmeth" : "#7D0552"
"helmeth" : "#7D0552"
"DAC" : "#E74C3C"
"co2 stored" : "#123456"
"CO2 sequestration" : "#123456"
"co2" : "#123456"
"Fischer-Tropsch" : "#44DD33"
"nuclear" : "#303030"
"water tanks" : "#BBBBBB"
"hot water storage" : "#BBBBBB"
"hot water charging" : "#BBBBBB"
"hot water discharging" : "#999999"
"CHP" : "r"
"CHP heat" : "r"
"CHP electric" : "r"
"PHS" : "g"
"Ambient" : "k"
"Electric load" : "b"
"Heat load" : "r"
"Transport load" : "grey"
"heat" : "darkred"
"heat demand" : "darkred"
"electric demand" : "k"
"Li ion" : "grey"
"district heating" : "#CC4E5C"
"retrofitting" : "purple"
"building retrofitting" : "purple"
"BEV charger" : "grey"
"V2G" : "grey"
"transport" : "grey"
"electricity" : "k"
"transport fuel cell" : "#AAAAAA"
"biogas" : "#800000"
"solid biomass" : "#DAA520"
"today" : "#D2691E"
nice_names:
# OCGT: "Gas"
# OCGT marginal: "Gas (marginal)"
offwind: "offshore wind"
onwind: "onshore wind"
battery: "Battery storage"
lines: "Transmission lines"
AC line: "AC lines"
AC-AC: "DC lines"
ror: "Run of river"
nice_names_n:
offwind: "offshore\nwind"
onwind: "onshore\nwind"
# OCGT: "Gas"
H2: "Hydrogen\nstorage"
# OCGT marginal: "Gas (marginal)"
lines: "transmission\nlines"
ror: "run of river"