pypsa-eur/config.tutorial.yaml
FabianHofmann 04f19f214d
fix emission prices (#171)
* fix emission prices

I'm not sure if the previous setup was intentional, but regarding that different generators might have different efficiencies and the emissions are carrier specific only, it makes more sense set net emission price.

* small fix

* update release_notes and config
2020-08-25 12:12:00 +02:00

333 lines
8.7 KiB
YAML
Executable File

# SPDX-FileCopyrightText: : 2017-2020 The PyPSA-Eur Authors
#
# SPDX-License-Identifier: CC0-1.0
version: 0.2.0
tutorial: true
logging:
level: INFO
format: '%(levelname)s:%(name)s:%(message)s'
summary_dir: results
scenario:
sectors: [E]
simpl: ['']
ll: ['copt']
clusters: [5]
opts: [Co2L-24H]
countries: ['DE']
snapshots:
start: "2013-03-01"
end: "2013-04-01"
closed: 'left' # end is not inclusive
enable:
prepare_links_p_nom: false
retrieve_databundle: true
build_cutout: false
retrieve_cutout: true
build_natura_raster: false
retrieve_natura_raster: true
electricity:
voltages: [220., 300., 380.]
co2limit: 100.e+6
extendable_carriers:
Generator: [OCGT]
StorageUnit: [battery, H2]
Store: [] #battery, H2
Link: []
max_hours:
battery: 6
H2: 168
powerplants_filter: false # use pandas query strings here, e.g. Country not in ['Germany']
custom_powerplants: false # use pandas query strings here, e.g. Country in ['Germany']
conventional_carriers: [coal, CCGT] # [nuclear, oil, OCGT, CCGT, coal, lignite, geothermal, biomass]
atlite:
nprocesses: 4
cutouts:
europe-2013-era5:
module: era5
xs: [4., 15.]
ys: [56., 46.]
months: [3, 3]
years: [2013, 2013]
renewable:
onwind:
cutout: europe-2013-era5
resource:
method: wind
turbine: Vestas_V112_3MW
capacity_per_sqkm: 3 # ScholzPhd Tab 4.3.1: 10MW/km^2
# correction_factor: 0.93
corine:
# Scholz, Y. (2012). Renewable energy based electricity supply at low costs:
# development of the REMix model and application for Europe. ( p.42 / p.28)
grid_codes: [12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23,
24, 25, 26, 27, 28, 29, 31, 32]
distance: 1000
distance_grid_codes: [1, 2, 3, 4, 5, 6]
natura: true
potential: simple # or conservative
clip_p_max_pu: 1.e-2
offwind-ac:
cutout: europe-2013-era5
resource:
method: wind
turbine: NREL_ReferenceTurbine_5MW_offshore
capacity_per_sqkm: 3
# correction_factor: 0.93
corine: [44, 255]
natura: true
max_shore_distance: 30000
potential: simple # or conservative
clip_p_max_pu: 1.e-2
offwind-dc:
cutout: europe-2013-era5
resource:
method: wind
turbine: NREL_ReferenceTurbine_5MW_offshore
# ScholzPhd Tab 4.3.1: 10MW/km^2
capacity_per_sqkm: 3
# correction_factor: 0.93
corine: [44, 255]
natura: true
min_shore_distance: 30000
potential: simple # or conservative
clip_p_max_pu: 1.e-2
solar:
cutout: europe-2013-era5
resource:
method: pv
panel: CSi
orientation:
slope: 35.
azimuth: 180.
capacity_per_sqkm: 1.7 # ScholzPhd Tab 4.3.1: 170 MW/km^2
# Determined by comparing uncorrected area-weighted full-load hours to those
# published in Supplementary Data to
# Pietzcker, Robert Carl, et al. "Using the sun to decarbonize the power
# sector: The economic potential of photovoltaics and concentrating solar
# power." Applied Energy 135 (2014): 704-720.
correction_factor: 0.854337
corine: [1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13,
14, 15, 16, 17, 18, 19, 20, 26, 31, 32]
natura: true
potential: simple # or conservative
clip_p_max_pu: 1.e-2
lines:
types:
220.: "Al/St 240/40 2-bundle 220.0"
300.: "Al/St 240/40 3-bundle 300.0"
380.: "Al/St 240/40 4-bundle 380.0"
s_max_pu: 0.7
length_factor: 1.25
under_construction: 'zero' # 'zero': set capacity to zero, 'remove': remove, 'keep': with full capacity
links:
p_max_pu: 1.0
include_tyndp: true
under_construction: 'zero' # 'zero': set capacity to zero, 'remove': remove, 'keep': with full capacity
transformers:
x: 0.1
s_nom: 2000.
type: ''
load:
scaling_factor: 1.0
costs:
year: 2030
discountrate: 0.07 # From a Lion Hirth paper, also reflects average of Noothout et al 2016
USD2013_to_EUR2013: 0.7532 # [EUR/USD] ECB: https://www.ecb.europa.eu/stats/exchange/eurofxref/html/eurofxref-graph-usd.en.html
marginal_cost:
solar: 0.01
onwind: 0.015
offwind: 0.015
H2: 0.
battery: 0.
emission_prices: # in currency per tonne emission, only used with the option Ep
co2: 0.
solving:
options:
formulation: kirchhoff
load_shedding: false
noisy_costs: true
min_iterations: 1
max_iterations: 1
clip_p_max_pu: 0.01
skip_iterations: false
track_iterations: false
#nhours: 10
solver:
name: cbc
# solver:
# name: gurobi
# threads: 4
# method: 2 # barrier
# crossover: 0
# BarConvTol: 1.e-5
# FeasibilityTol: 1.e-6
# AggFill: 0
# PreDual: 0
# GURO_PAR_BARDENSETHRESH: 200
# solver:
# name: cplex
# threads: 4
# lpmethod: 4 # barrier
# solutiontype: 2 # non basic solution, ie no crossover
# barrier_convergetol: 1.e-5
# feasopt_tolerance: 1.e-6
plotting:
map:
figsize: [7, 7]
boundaries: [-10.2, 29, 35, 72]
p_nom:
bus_size_factor: 5.e+4
linewidth_factor: 3.e+3
costs_max: 800
costs_threshold: 1
energy_max: 15000.
energy_min: -10000.
energy_threshold: 50.
vre_techs: ["onwind", "offwind-ac", "offwind-dc", "solar", "ror"]
conv_techs: ["OCGT", "CCGT", "Nuclear", "Coal"]
storage_techs: ["hydro+PHS", "battery", "H2"]
load_carriers: ["AC load"]
AC_carriers: ["AC line", "AC transformer"]
link_carriers: ["DC line", "Converter AC-DC"]
tech_colors:
"onwind" : "#235ebc"
"onshore wind" : "#235ebc"
'offwind' : "#6895dd"
'offwind-ac' : "#6895dd"
'offshore wind' : "#6895dd"
'offshore wind ac' : "#6895dd"
'offwind-dc' : "#74c6f2"
'offshore wind dc' : "#74c6f2"
"hydro" : "#08ad97"
"hydro+PHS" : "#08ad97"
"PHS" : "#08ad97"
"hydro reservoir" : "#08ad97"
'hydroelectricity' : '#08ad97'
"ror" : "#4adbc8"
"run of river" : "#4adbc8"
'solar' : "#f9d002"
'solar PV' : "#f9d002"
'solar thermal' : '#ffef60'
'biomass' : '#0c6013'
'solid biomass' : '#06540d'
'biogas' : '#23932d'
'waste' : '#68896b'
'geothermal' : '#ba91b1'
"OCGT" : "#d35050"
"OCGT marginal" : "#d35050"
"OCGT-heat" : "#d35050"
"gas boiler" : "#d35050"
"gas boilers" : "#d35050"
"gas boiler marginal" : "#d35050"
"gas-to-power/heat" : "#d35050"
"gas" : "#d35050"
"natural gas" : "#d35050"
"CCGT" : "#b20101"
"CCGT marginal" : "#b20101"
"Nuclear" : "#ff9000"
"Nuclear marginal" : "#ff9000"
"nuclear" : "#ff9000"
"coal" : "#707070"
"Coal" : "#707070"
"Coal marginal" : "#707070"
"lignite" : "#9e5a01"
"Lignite" : "#9e5a01"
"Lignite marginal" : "#9e5a01"
"Oil" : "#262626"
"oil" : "#262626"
"H2" : "#ea048a"
"hydrogen storage" : "#ea048a"
"Sabatier" : "#a31597"
"methanation" : "#a31597"
"helmeth" : "#a31597"
"DAC" : "#d284ff"
"co2 stored" : "#e5e5e5"
"CO2 sequestration" : "#e5e5e5"
"battery" : "#b8ea04"
"battery storage" : "#b8ea04"
"Li ion" : "#b8ea04"
"BEV charger" : "#e2ff7c"
"V2G" : "#7a9618"
"transport fuel cell" : "#e884be"
"retrofitting" : "#e0d6a8"
"building retrofitting" : "#e0d6a8"
"heat pumps" : "#ff9768"
"heat pump" : "#ff9768"
"air heat pump" : "#ffbea0"
"ground heat pump" : "#ff7a3d"
"power-to-heat" : "#a59e7c"
"power-to-gas" : "#db8585"
"power-to-liquid" : "#a9acd1"
"Fischer-Tropsch" : "#a9acd1"
"resistive heater" : "#aa4925"
"water tanks" : "#401f75"
"hot water storage" : "#401f75"
"hot water charging" : "#351c5e"
"hot water discharging" : "#683ab2"
"CHP" : "#d80a56"
"CHP heat" : "#d80a56"
"CHP electric" : "#d80a56"
"district heating" : "#93864b"
"Ambient" : "#262626"
"Electric load" : "#f9d002"
"electricity" : "#f9d002"
"Heat load" : "#d35050"
"heat" : "#d35050"
"Transport load" : "#235ebc"
"transport" : "#235ebc"
"lines" : "#70af1d"
"transmission lines" : "#70af1d"
"AC-AC" : "#70af1d"
"AC line" : "#70af1d"
"links" : "#8a1caf"
"HVDC links" : "#8a1caf"
"DC-DC" : "#8a1caf"
"DC link" : "#8a1caf"
nice_names:
OCGT: "Open-Cycle Gas"
CCGT: "Combined-Cycle Gas"
offwind-ac: "Offshore Wind (AC)"
offwind-dc: "Offshore Wind (DC)"
onwind: "Onshore Wind"
solar: "Solar"
PHS: "Pumped Hydro Storage"
hydro: "Reservoir & Dam"
battery: "Battery Storage"
H2: "Hydrogen Storage"
lines: "Transmission lines"
ror: "Run of river"
nice_names_n:
OCGT: "Open-Cycle\nGas"
CCGT: "Combined-Cycle\nGas"
offwind-ac: "Offshore\nWind (AC)"
offwind-dc: "Offshore\nWind (DC)"
onwind: "Onshore\nWind"
battery: "Battery\nStorage"
H2: "Hydrogen\nStorage"
lines: "Transmission\nlines"
ror: "Run of\nriver"
PHS: "Pumped Hydro\nStorage"
hydro: "Reservoir\n& Dam"