commit
ff92f14974
@ -597,6 +597,7 @@ sector:
|
|||||||
conventional_generation:
|
conventional_generation:
|
||||||
OCGT: gas
|
OCGT: gas
|
||||||
biomass_to_liquid: false
|
biomass_to_liquid: false
|
||||||
|
electrobiofuels: false
|
||||||
biosng: false
|
biosng: false
|
||||||
limit_max_growth:
|
limit_max_growth:
|
||||||
enable: false
|
enable: false
|
||||||
@ -1029,6 +1030,7 @@ plotting:
|
|||||||
services rural biomass boiler: '#c6cf98'
|
services rural biomass boiler: '#c6cf98'
|
||||||
services urban decentral biomass boiler: '#dde5b5'
|
services urban decentral biomass boiler: '#dde5b5'
|
||||||
biomass to liquid: '#32CD32'
|
biomass to liquid: '#32CD32'
|
||||||
|
electrobiofuels: 'red'
|
||||||
BioSNG: '#123456'
|
BioSNG: '#123456'
|
||||||
# power transmission
|
# power transmission
|
||||||
lines: '#6c9459'
|
lines: '#6c9459'
|
||||||
|
@ -138,6 +138,7 @@ biomass_transport,--,"{true, false}",Add option for transporting solid biomass b
|
|||||||
biogas_upgrading_cc,--,"{true, false}",Add option to capture CO2 from biomass upgrading
|
biogas_upgrading_cc,--,"{true, false}",Add option to capture CO2 from biomass upgrading
|
||||||
conventional_generation,,,Add a more detailed description of conventional carriers. Any power generation requires the consumption of fuel from nodes representing that fuel.
|
conventional_generation,,,Add a more detailed description of conventional carriers. Any power generation requires the consumption of fuel from nodes representing that fuel.
|
||||||
biomass_to_liquid,--,"{true, false}",Add option for transforming solid biomass into liquid fuel with the same properties as oil
|
biomass_to_liquid,--,"{true, false}",Add option for transforming solid biomass into liquid fuel with the same properties as oil
|
||||||
|
electrobiofuels,--,"{true, false}","Add option for transforming solid biomass and hydrogen into liquid fuel to make more use of biogenic carbon, as a combination of BtL and Fischer-Tropsch"
|
||||||
biosng,--,"{true, false}",Add option for transforming solid biomass into synthesis gas with the same properties as natural gas
|
biosng,--,"{true, false}",Add option for transforming solid biomass into synthesis gas with the same properties as natural gas
|
||||||
limit_max_growth,,,
|
limit_max_growth,,,
|
||||||
-- enable,--,"{true, false}",Add option to limit the maximum growth of a carrier
|
-- enable,--,"{true, false}",Add option to limit the maximum growth of a carrier
|
||||||
|
|
@ -10,6 +10,8 @@ Release Notes
|
|||||||
Upcoming Release
|
Upcoming Release
|
||||||
================
|
================
|
||||||
|
|
||||||
|
* Add option to produce electrobiofuels from solid biomass and hydrogen, as a combination of BtL and Fischer-Tropsch to make more use of the biogenic carbon
|
||||||
|
|
||||||
* Add flag ``sector: fossil_fuels`` in config to remove the option of importing fossil fuels
|
* Add flag ``sector: fossil_fuels`` in config to remove the option of importing fossil fuels
|
||||||
|
|
||||||
* Renamed the carrier of batteries in BEVs from `battery storage` to `EV battery` and the corresponding bus carrier from `Li ion` to `EV battery`. This is to avoid confusion with stationary battery storage.
|
* Renamed the carrier of batteries in BEVs from `battery storage` to `EV battery` and the corresponding bus carrier from `Li ion` to `EV battery`. This is to avoid confusion with stationary battery storage.
|
||||||
|
@ -2511,6 +2511,43 @@ def add_biomass(n, costs):
|
|||||||
marginal_cost=costs.at["BtL", "efficiency"] * costs.at["BtL", "VOM"],
|
marginal_cost=costs.at["BtL", "efficiency"] * costs.at["BtL", "VOM"],
|
||||||
)
|
)
|
||||||
|
|
||||||
|
# Electrobiofuels (BtL with hydrogen addition to make more use of biogenic carbon).
|
||||||
|
# Combination of efuels and biomass to liquid, both based on Fischer-Tropsch.
|
||||||
|
# Experimental version - use with caution
|
||||||
|
if options["electrobiofuels"]:
|
||||||
|
|
||||||
|
efuel_scale_factor = costs.at["BtL", "C stored"]
|
||||||
|
name = (
|
||||||
|
pd.Index(spatial.biomass.nodes)
|
||||||
|
+ " "
|
||||||
|
+ pd.Index(spatial.h2.nodes.str.replace(" H2", ""))
|
||||||
|
)
|
||||||
|
n.madd(
|
||||||
|
"Link",
|
||||||
|
name,
|
||||||
|
suffix=" electrobiofuels",
|
||||||
|
bus0=spatial.biomass.nodes,
|
||||||
|
bus1=spatial.oil.nodes,
|
||||||
|
bus2=spatial.h2.nodes,
|
||||||
|
bus3="co2 atmosphere",
|
||||||
|
carrier="electrobiofuels",
|
||||||
|
lifetime=costs.at["electrobiofuels", "lifetime"],
|
||||||
|
efficiency=costs.at["electrobiofuels", "efficiency-biomass"],
|
||||||
|
efficiency2=-costs.at["electrobiofuels", "efficiency-hydrogen"],
|
||||||
|
efficiency3=-costs.at["solid biomass", "CO2 intensity"]
|
||||||
|
+ costs.at["BtL", "CO2 stored"]
|
||||||
|
* (1 - costs.at["Fischer-Tropsch", "capture rate"]),
|
||||||
|
p_nom_extendable=True,
|
||||||
|
capital_cost=costs.at["BtL", "fixed"] * costs.at["BtL", "efficiency"]
|
||||||
|
+ efuel_scale_factor
|
||||||
|
* costs.at["Fischer-Tropsch", "fixed"]
|
||||||
|
* costs.at["Fischer-Tropsch", "efficiency"],
|
||||||
|
marginal_cost=costs.at["BtL", "VOM"] * costs.at["BtL", "efficiency"]
|
||||||
|
+ efuel_scale_factor
|
||||||
|
* costs.at["Fischer-Tropsch", "VOM"]
|
||||||
|
* costs.at["Fischer-Tropsch", "efficiency"],
|
||||||
|
)
|
||||||
|
|
||||||
# BioSNG from solid biomass
|
# BioSNG from solid biomass
|
||||||
if options["biosng"]:
|
if options["biosng"]:
|
||||||
n.madd(
|
n.madd(
|
||||||
|
Loading…
Reference in New Issue
Block a user