config: remove unneeded plotting entries
This commit is contained in:
parent
0664f1050f
commit
9c6e5e0ed0
@ -665,48 +665,6 @@ plotting:
|
||||
energy_max: 20000
|
||||
energy_min: -20000
|
||||
energy_threshold: 50.
|
||||
vre_techs:
|
||||
- onwind
|
||||
- offwind-ac
|
||||
- offwind-dc
|
||||
- solar
|
||||
- ror
|
||||
renewable_storage_techs:
|
||||
- PHS
|
||||
- hydro
|
||||
conv_techs:
|
||||
- OCGT
|
||||
- CCGT
|
||||
- Nuclear
|
||||
- Coal
|
||||
storage_techs:
|
||||
- hydro+PHS
|
||||
- battery
|
||||
- H2
|
||||
load_carriers:
|
||||
- AC load
|
||||
AC_carriers:
|
||||
- AC line
|
||||
- AC transformer
|
||||
link_carriers:
|
||||
- DC line
|
||||
- Converter AC-DC
|
||||
heat_links:
|
||||
- heat pump
|
||||
- resistive heater
|
||||
- CHP heat
|
||||
- CHP electric
|
||||
- gas boiler
|
||||
- central heat pump
|
||||
- central resistive heater
|
||||
- central CHP heat
|
||||
- central CHP electric
|
||||
- central gas boiler
|
||||
heat_generators:
|
||||
- gas boiler
|
||||
- central gas boiler
|
||||
- solar thermal collector
|
||||
- central solar thermal collector
|
||||
|
||||
nice_names:
|
||||
OCGT: "Open-Cycle Gas"
|
||||
|
@ -7,13 +7,4 @@ energy_max,TWh,float,Upper y-axis limit in energy bar plots.
|
||||
energy_min,TWh,float,Lower y-axis limit in energy bar plots.
|
||||
energy_threshold,TWh,float,Threshold below which technologies will not be shown in energy bar plots.
|
||||
tech_colors,--,carrier -> HEX colour code,Mapping from network ``carrier`` to a colour (`HEX colour code <https://en.wikipedia.org/wiki/Web_colors#Hex_triplet>`_).
|
||||
vre_techs ,--,subset of carriers,Value not in use
|
||||
renewable_storage_techs ,--,subset of carriers,Value not in use
|
||||
conv_techs ,--,subset of carriers,Value in use with unworthy significance. Used as the definition of conventional carrier in solve_network
|
||||
storage_techs ,--,subset of carriers,Value not in use
|
||||
load_carriers ,--,subset of carriers,Value not in use
|
||||
AC_carriers ,--,subset of carriers,Value not in use
|
||||
link_carriers ,--,subset of carriers,Value not in use
|
||||
heat_links ,--,subset of carriers,Value not in use
|
||||
heat_generators ,--,subset of carriers,Value not in use
|
||||
nice_names,--,str -> str,Mapping from network ``carrier`` to a more readable name.
|
||||
|
|
@ -378,13 +378,14 @@ def add_SAFE_constraints(n, config):
|
||||
peakdemand = n.loads_t.p_set.sum(axis=1).max()
|
||||
margin = 1.0 + config["electricity"]["SAFE_reservemargin"]
|
||||
reserve_margin = peakdemand * margin
|
||||
# TODO: do not take this from the plotting config!
|
||||
conv_techs = config["plotting"]["conv_techs"]
|
||||
ext_gens_i = n.generators.query("carrier in @conv_techs & p_nom_extendable").index
|
||||
conventional_carriers = config["electricity"]["conventional_carriers"]
|
||||
ext_gens_i = n.generators.query(
|
||||
"carrier in @conventional_carriers & p_nom_extendable"
|
||||
).index
|
||||
p_nom = n.model["Generator-p_nom"].loc[ext_gens_i]
|
||||
lhs = p_nom.sum()
|
||||
exist_conv_caps = n.generators.query(
|
||||
"~p_nom_extendable & carrier in @conv_techs"
|
||||
"~p_nom_extendable & carrier in @conventional_carriers"
|
||||
).p_nom.sum()
|
||||
rhs = reserve_margin - exist_conv_caps
|
||||
n.model.add_constraints(lhs >= rhs, name="safe_mintotalcap")
|
||||
|
Loading…
Reference in New Issue
Block a user