prevent failure if potential waste heat technologies not present
This commit is contained in:
parent
777899f686
commit
71b27b524e
@ -2974,8 +2974,10 @@ def add_waste_heat(n):
|
|||||||
if not urban_central.empty:
|
if not urban_central.empty:
|
||||||
urban_central = urban_central.str[: -len(" urban central heat")]
|
urban_central = urban_central.str[: -len(" urban central heat")]
|
||||||
|
|
||||||
|
link_carriers = n.links.carrier.unique()
|
||||||
|
|
||||||
# TODO what is the 0.95 and should it be a config option?
|
# TODO what is the 0.95 and should it be a config option?
|
||||||
if options["use_fischer_tropsch_waste_heat"]:
|
if options["use_fischer_tropsch_waste_heat"] and "Fischer-Tropsch" in link_carriers:
|
||||||
n.links.loc[urban_central + " Fischer-Tropsch", "bus3"] = (
|
n.links.loc[urban_central + " Fischer-Tropsch", "bus3"] = (
|
||||||
urban_central + " urban central heat"
|
urban_central + " urban central heat"
|
||||||
)
|
)
|
||||||
@ -2983,7 +2985,7 @@ def add_waste_heat(n):
|
|||||||
0.95 - n.links.loc[urban_central + " Fischer-Tropsch", "efficiency"]
|
0.95 - n.links.loc[urban_central + " Fischer-Tropsch", "efficiency"]
|
||||||
)
|
)
|
||||||
|
|
||||||
if options["use_methanation_waste_heat"]:
|
if options["use_methanation_waste_heat"] and "Sabatier" in link_carriers:
|
||||||
n.links.loc[urban_central + " Sabatier", "bus3"] = (
|
n.links.loc[urban_central + " Sabatier", "bus3"] = (
|
||||||
urban_central + " urban central heat"
|
urban_central + " urban central heat"
|
||||||
)
|
)
|
||||||
@ -2992,7 +2994,7 @@ def add_waste_heat(n):
|
|||||||
)
|
)
|
||||||
|
|
||||||
# DEA quotes 15% of total input (11% of which are high-value heat)
|
# DEA quotes 15% of total input (11% of which are high-value heat)
|
||||||
if options["use_haber_bosch_waste_heat"]:
|
if options["use_haber_bosch_waste_heat"] and "Haber-Bosch" in link_carriers:
|
||||||
n.links.loc[urban_central + " Haber-Bosch", "bus3"] = (
|
n.links.loc[urban_central + " Haber-Bosch", "bus3"] = (
|
||||||
urban_central + " urban central heat"
|
urban_central + " urban central heat"
|
||||||
)
|
)
|
||||||
@ -3008,7 +3010,7 @@ def add_waste_heat(n):
|
|||||||
0.15 * total_energy_input / electricity_input
|
0.15 * total_energy_input / electricity_input
|
||||||
)
|
)
|
||||||
|
|
||||||
if options["use_methanolisation_waste_heat"]:
|
if options["use_methanolisation_waste_heat"] and "methanolisation" in link_carriers:
|
||||||
n.links.loc[urban_central + " methanolisation", "bus4"] = (
|
n.links.loc[urban_central + " methanolisation", "bus4"] = (
|
||||||
urban_central + " urban central heat"
|
urban_central + " urban central heat"
|
||||||
)
|
)
|
||||||
@ -3018,7 +3020,7 @@ def add_waste_heat(n):
|
|||||||
)
|
)
|
||||||
|
|
||||||
# TODO integrate usable waste heat efficiency into technology-data from DEA
|
# TODO integrate usable waste heat efficiency into technology-data from DEA
|
||||||
if options.get("use_electrolysis_waste_heat", False):
|
if options.get("use_electrolysis_waste_heat", False) and "H2 Electrolysis" in link_carriers:
|
||||||
n.links.loc[urban_central + " H2 Electrolysis", "bus2"] = (
|
n.links.loc[urban_central + " H2 Electrolysis", "bus2"] = (
|
||||||
urban_central + " urban central heat"
|
urban_central + " urban central heat"
|
||||||
)
|
)
|
||||||
@ -3026,7 +3028,7 @@ def add_waste_heat(n):
|
|||||||
0.84 - n.links.loc[urban_central + " H2 Electrolysis", "efficiency"]
|
0.84 - n.links.loc[urban_central + " H2 Electrolysis", "efficiency"]
|
||||||
)
|
)
|
||||||
|
|
||||||
if options["use_fuel_cell_waste_heat"]:
|
if options["use_fuel_cell_waste_heat"] and "H2 Fuel Cell" in link_carriers:
|
||||||
n.links.loc[urban_central + " H2 Fuel Cell", "bus2"] = (
|
n.links.loc[urban_central + " H2 Fuel Cell", "bus2"] = (
|
||||||
urban_central + " urban central heat"
|
urban_central + " urban central heat"
|
||||||
)
|
)
|
||||||
|
Loading…
Reference in New Issue
Block a user