edit configtables and accept Fneum suggestion
This commit is contained in:
parent
bc6cc6c983
commit
657dd08b53
@ -218,6 +218,7 @@ renewable:
|
||||
PHS_max_hours: 6
|
||||
hydro_max_hours: "energy_capacity_totals_by_country" # one of energy_capacity_totals_by_country, estimate_by_large_installations or a float
|
||||
flatten_dispatch: false
|
||||
flatten_dispatch_buffer: 0.2
|
||||
clip_min_inflow: 1.0
|
||||
|
||||
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#conventional
|
||||
|
@ -1,7 +1,5 @@
|
||||
,Unit,Values,Description
|
||||
{name},--,string,For any carrier/technology overwrite attributes as listed below.
|
||||
-- {attribute},--,string or float,"For any attribute, can specify a float or reference to a file path to a CSV file giving floats for each country (2-letter code)."
|
||||
unit_commitment ,bool,"{true, false}","Allow the overwrite of ramp_limit_up, ramp_limit_start_up, ramp_limit_shut_down, p_min_pu, min_up_time, min_down_time, and start_up_cost of conventional generators. Refer to the CSV file „unit_commitment.csv“."
|
||||
dynamic_fuel_price ,bool,"{true, false}","Consider the monthly fluctuating fuel prices for each conventional generator. Refer to the CSV file ""data/validation/monthly_fuel_price.csv""."
|
||||
nuclear ,,,
|
||||
-- p_max_pu,--,string or float ,Specify a float or reference to a file path to a CSV file the maximum dispatch for nuclear power plants in each country (2-letter code)
|
||||
{name},--,string,For any carrier/technology overwrite attributes as listed below.
|
||||
-- {attribute},--,string or float,"For any attribute, can specify a float or reference to a file path to a CSV file giving floats for each country (2-letter code)."
|
||||
|
|
@ -3,5 +3,6 @@ cutout,--,Must be 'europe-2013-era5',Specifies the directory where the relevant
|
||||
carriers,--,"Any subset of {'ror', 'PHS', 'hydro'}","Specifies the types of hydro power plants to build per-unit availability time series for. 'ror' stands for run-of-river plants, 'PHS' represents pumped-hydro storage, and 'hydro' stands for hydroelectric dams."
|
||||
PHS_max_hours,h,float,Maximum state of charge capacity of the pumped-hydro storage (PHS) in terms of hours at full output capacity ``p_nom``. Cf. `PyPSA documentation <https://pypsa.readthedocs.io/en/latest/components.html#storage-unit>`_.
|
||||
hydro_max_hours,h,"Any of {float, 'energy_capacity_totals_by_country', 'estimate_by_large_installations'}",Maximum state of charge capacity of the pumped-hydro storage (PHS) in terms of hours at full output capacity ``p_nom`` or heuristically determined. Cf. `PyPSA documentation <https://pypsa.readthedocs.io/en/latest/components.html#storage-unit>`_.
|
||||
flatten_dispatch,bool or float,"{true, false, float}","Enables the flattening of the hydro-dispatch. If bool is specified, it represents the buffer value where the maximum hydro dispatch is equal to the average capacity factor plus the buffer with a maximum value of 1. If true is specified, the buffer value is 0.2. Otherwise, the maximum hydro dispatch remains equal to 1."
|
||||
flatten_dispatch,bool,"{true, false}",Consider an upper limit for the hydro dispatch. The limit is given by the average capacity factor plus the buffer given in ``flatten_dispatch_buffer``
|
||||
flatten_dispatch_buffer,--,float,"If ``flatten_dispatch`` is true, specify the value added above the average capacity factor."
|
||||
clip_min_inflow,MW,float,"To avoid too small values in the inflow time series, values below this threshold are set to zero."
|
||||
|
|
@ -4,14 +4,14 @@ options,,,
|
||||
-- load_shedding,bool/float,"{'true','false', float}","Add generators with very high marginal cost to simulate load shedding and avoid problem infeasibilities. If load shedding is a float, it denotes the marginal cost in EUR/kWh."
|
||||
-- noisy_costs,bool,"{'true','false'}","Add random noise to marginal cost of generators by :math:`\mathcal{U}(0.009,0,011)` and capital cost of lines and links by :math:`\mathcal{U}(0.09,0,11)`."
|
||||
-- skip_iterations,bool,"{'true','false'}","Skip iterating, do not update impedances of branches. Defaults to true."
|
||||
-- rolling_horizon,bool,"{'true','false'}",
|
||||
-- rolling_horizon,bool,"{'true','false'}","Whether to optimize the network in a rolling horizon manner, where the snapshot range is split into slices of size `horizon` which are solved consecutively."
|
||||
-- seed,--,int,Random seed for increased deterministic behaviour.
|
||||
-- track_iterations,bool,"{'true','false'}",Flag whether to store the intermediate branch capacities and objective function values are recorded for each iteration in ``network.lines['s_nom_opt_X']`` (where ``X`` labels the iteration)
|
||||
-- min_iterations,--,int,Minimum number of solving iterations in between which resistance and reactence (``x/r``) are updated for branches according to ``s_nom_opt`` of the previous run.
|
||||
-- max_iterations,--,int,Maximum number of solving iterations in between which resistance and reactence (``x/r``) are updated for branches according to ``s_nom_opt`` of the previous run.
|
||||
-- transmission_losses,int,[0-9],"Add piecewise linear approximation of transmission losses based on n tangents. Defaults to 0, which means losses are ignored."
|
||||
-- linearized_unit_commitment,bool,"{'true','false'}",
|
||||
-- horizon,--,int,
|
||||
-- linearized_unit_commitment,bool,"{'true','false'}",Whether to optimise using the linearized unit commitment formulation.
|
||||
-- horizon,--,int,Number of snapshots to consider in each iteration. Defaults to 100.
|
||||
solver,,,
|
||||
-- name,--,"One of {'gurobi', 'cplex', 'cbc', 'glpk', 'ipopt'}; potentially more possible",Solver to use for optimisation problems in the workflow; e.g. clustering and linear optimal power flow.
|
||||
-- options,--,Key listed under ``solver_options``.,Link to specific parameter settings.
|
||||
|
|
@ -6,7 +6,7 @@ logging,,,
|
||||
-- format,--,,Custom format for log messages. See `LogRecord <https://docs.python.org/3/library/logging.html#logging.LogRecord>`_ attributes.
|
||||
private,,,
|
||||
-- keys,,,
|
||||
-- -- entsoe_api,--,,Specify the ENTSO-E API key. See the guidelines to get `ENTSO-E API key <https://transparency.entsoe.eu/content/static_content/Static%20content/web%20api/Guide.html>`_
|
||||
-- -- entsoe_api,--,,Optionally specify the ENTSO-E API key. See the guidelines to get `ENTSO-E API key <https://transparency.entsoe.eu/content/static_content/Static%20content/web%20api/Guide.html>`_
|
||||
remote,,,
|
||||
-- ssh,--,,Specify the SSH of a remote cluster to be synchronized.
|
||||
-- path,--,,Specify the file path within the remote cluster to be synchronized.
|
||||
-- ssh,--,,Optionally specify the SSH of a remote cluster to be synchronized.
|
||||
-- path,--,,Optionally specify the file path within the remote cluster to be synchronized.
|
||||
|
|
@ -619,9 +619,7 @@ def attach_hydro(n, costs, ppl, profile_hydro, hydro_capacities, carriers, **par
|
||||
|
||||
flatten_dispatch = params.get("flatten_dispatch", False)
|
||||
if flatten_dispatch:
|
||||
buffer = (
|
||||
flatten_dispatch if isinstance(flatten_dispatch, (int, float)) else 0.2
|
||||
)
|
||||
buffer = params.get("flatten_dispatch_buffer", 0.2)
|
||||
average_capacity_factor = inflow_t[hydro.index].mean() / hydro["p_nom"]
|
||||
p_max_pu = (average_capacity_factor + buffer).clip(upper=1)
|
||||
else:
|
||||
|
Loading…