@ -420,8 +420,8 @@ hydro,2020,FOM,1.0,%/year,DIW DataDoc http://hdl.handle.net/10419/80348," from o
|
|||||||
hydro,2020,efficiency,0.9,per unit,DIW DataDoc http://hdl.handle.net/10419/80348," from old pypsa cost assumptions"
|
hydro,2020,efficiency,0.9,per unit,DIW DataDoc http://hdl.handle.net/10419/80348," from old pypsa cost assumptions"
|
||||||
hydro,2020,investment,2208.16,EUR/kWel,DIW DataDoc http://hdl.handle.net/10419/80348," from old pypsa cost assumptions"
|
hydro,2020,investment,2208.16,EUR/kWel,DIW DataDoc http://hdl.handle.net/10419/80348," from old pypsa cost assumptions"
|
||||||
hydro,2020,lifetime,80.0,years,IEA2010," from old pypsa cost assumptions"
|
hydro,2020,lifetime,80.0,years,IEA2010," from old pypsa cost assumptions"
|
||||||
hydrogen storage tank,2020,investment,11.2,USD/kWh,budischak2013," from old pypsa cost assumptions"
|
hydrogen storage,2020,investment,11.2,USD/kWh,budischak2013," from old pypsa cost assumptions"
|
||||||
hydrogen storage tank,2020,lifetime,20.0,years,budischak2013," from old pypsa cost assumptions"
|
hydrogen storage,2020,lifetime,20.0,years,budischak2013," from old pypsa cost assumptions"
|
||||||
hydrogen storage tank incl. compressor,2020,FOM,1.05,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",151a Hydrogen Storage - Tanks: Fixed O&M
|
hydrogen storage tank incl. compressor,2020,FOM,1.05,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",151a Hydrogen Storage - Tanks: Fixed O&M
|
||||||
hydrogen storage tank incl. compressor,2020,investment,57.0,EUR/kWh,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",151a Hydrogen Storage - Tanks: Specific investment
|
hydrogen storage tank incl. compressor,2020,investment,57.0,EUR/kWh,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",151a Hydrogen Storage - Tanks: Specific investment
|
||||||
hydrogen storage tank incl. compressor,2020,lifetime,25.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",151a Hydrogen Storage - Tanks: Technical lifetime
|
hydrogen storage tank incl. compressor,2020,lifetime,25.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",151a Hydrogen Storage - Tanks: Technical lifetime
|
||||||
@ -950,8 +950,8 @@ hydro,2030,FOM,1.0,%/year,DIW DataDoc http://hdl.handle.net/10419/80348," from o
|
|||||||
hydro,2030,efficiency,0.9,per unit,DIW DataDoc http://hdl.handle.net/10419/80348," from old pypsa cost assumptions"
|
hydro,2030,efficiency,0.9,per unit,DIW DataDoc http://hdl.handle.net/10419/80348," from old pypsa cost assumptions"
|
||||||
hydro,2030,investment,2208.16,EUR/kWel,DIW DataDoc http://hdl.handle.net/10419/80348," from old pypsa cost assumptions"
|
hydro,2030,investment,2208.16,EUR/kWel,DIW DataDoc http://hdl.handle.net/10419/80348," from old pypsa cost assumptions"
|
||||||
hydro,2030,lifetime,80.0,years,IEA2010," from old pypsa cost assumptions"
|
hydro,2030,lifetime,80.0,years,IEA2010," from old pypsa cost assumptions"
|
||||||
hydrogen storage tank,2030,investment,11.2,USD/kWh,budischak2013," from old pypsa cost assumptions"
|
hydrogen storage,2030,investment,11.2,USD/kWh,budischak2013," from old pypsa cost assumptions"
|
||||||
hydrogen storage tank,2030,lifetime,20.0,years,budischak2013," from old pypsa cost assumptions"
|
hydrogen storage,2030,lifetime,20.0,years,budischak2013," from old pypsa cost assumptions"
|
||||||
hydrogen storage tank incl. compressor,2030,FOM,1.11,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",151a Hydrogen Storage - Tanks: Fixed O&M
|
hydrogen storage tank incl. compressor,2030,FOM,1.11,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",151a Hydrogen Storage - Tanks: Fixed O&M
|
||||||
hydrogen storage tank incl. compressor,2030,investment,44.91,EUR/kWh,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",151a Hydrogen Storage - Tanks: Specific investment
|
hydrogen storage tank incl. compressor,2030,investment,44.91,EUR/kWh,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",151a Hydrogen Storage - Tanks: Specific investment
|
||||||
hydrogen storage tank incl. compressor,2030,lifetime,30.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",151a Hydrogen Storage - Tanks: Technical lifetime
|
hydrogen storage tank incl. compressor,2030,lifetime,30.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",151a Hydrogen Storage - Tanks: Technical lifetime
|
||||||
|
|
@ -168,7 +168,7 @@ def load_costs(tech_costs, config, elec_config, Nyears=1.):
|
|||||||
costs_for_storage(costs.loc["battery storage"], costs.loc["battery inverter"],
|
costs_for_storage(costs.loc["battery storage"], costs.loc["battery inverter"],
|
||||||
max_hours=max_hours['battery'])
|
max_hours=max_hours['battery'])
|
||||||
costs.loc["H2"] = \
|
costs.loc["H2"] = \
|
||||||
costs_for_storage(costs.loc["hydrogen storage tank"], costs.loc["fuel cell"],
|
costs_for_storage(costs.loc["hydrogen storage"], costs.loc["fuel cell"],
|
||||||
costs.loc["electrolysis"], max_hours=max_hours['H2'])
|
costs.loc["electrolysis"], max_hours=max_hours['H2'])
|
||||||
|
|
||||||
for attr in ('marginal_cost', 'capital_cost'):
|
for attr in ('marginal_cost', 'capital_cost'):
|
||||||
|