costs: Add lifetimes for biomass, oil and nuclear from ECF2010

This commit is contained in:
Jonas Hörsch 2018-07-26 00:01:07 +02:00
parent e2a67d624f
commit 23ebcaeaa0

View File

@ -9,11 +9,13 @@ PHS,2030,lifetime,80,years,IEA2010
hydro,2030,lifetime,80,years,IEA2010
ror,2030,lifetime,80,years,IEA2010
OCGT,2030,lifetime,30,years,IEA2010
nuclear,2030,lifetime,60,years,IEA2010 (40 years are probably more representative)
nuclear,2030,lifetime,45,years,ECF2010 in DIW DataDoc http://hdl.handle.net/10419/80348
CCGT,2030,lifetime,30,years,IEA2010
coal,2030,lifetime,40,years,IEA2010
lignite,2030,lifetime,40,years,IEA2010
geothermal,2030,lifetime,40,years,IEA2010
biomass,2030,lifetime,30,years,ECF2010 in DIW DataDoc http://hdl.handle.net/10419/80348
oil,2030,lifetime,30,years,ECF2010 in DIW DataDoc http://hdl.handle.net/10419/80348
onwind,2030,investment,1182,EUR/kWel,DIW DataDoc http://hdl.handle.net/10419/80348
offwind,2030,investment,2506,EUR/kWel,DIW DataDoc http://hdl.handle.net/10419/80348
solar,2030,investment,600,EUR/kWel,DIW DataDoc http://hdl.handle.net/10419/80348

1 technology year parameter value unit source
9 hydro 2030 lifetime 80 years IEA2010
10 ror 2030 lifetime 80 years IEA2010
11 OCGT 2030 lifetime 30 years IEA2010
12 nuclear 2030 lifetime 60 45 years IEA2010 (40 years are probably more representative) ECF2010 in DIW DataDoc http://hdl.handle.net/10419/80348
13 CCGT 2030 lifetime 30 years IEA2010
14 coal 2030 lifetime 40 years IEA2010
15 lignite 2030 lifetime 40 years IEA2010
16 geothermal 2030 lifetime 40 years IEA2010
17 biomass 2030 lifetime 30 years ECF2010 in DIW DataDoc http://hdl.handle.net/10419/80348
18 oil 2030 lifetime 30 years ECF2010 in DIW DataDoc http://hdl.handle.net/10419/80348
19 onwind 2030 investment 1182 EUR/kWel DIW DataDoc http://hdl.handle.net/10419/80348
20 offwind 2030 investment 2506 EUR/kWel DIW DataDoc http://hdl.handle.net/10419/80348
21 solar 2030 investment 600 EUR/kWel DIW DataDoc http://hdl.handle.net/10419/80348