Merge pull request #179 from PyPSA/new-colors
add new color scheme for more distinguishing colors
This commit is contained in:
commit
0e1bf531cb
@ -413,6 +413,7 @@ plotting:
|
||||
- solar thermal collector
|
||||
- central solar thermal collector
|
||||
tech_colors:
|
||||
# wind
|
||||
onwind: "#235ebc"
|
||||
onshore wind: "#235ebc"
|
||||
offwind: "#6895dd"
|
||||
@ -421,123 +422,160 @@ plotting:
|
||||
offshore wind (AC): "#6895dd"
|
||||
offwind-dc: "#74c6f2"
|
||||
offshore wind (DC): "#74c6f2"
|
||||
wave: '#004444'
|
||||
hydro: '#3B5323'
|
||||
hydro reservoir: '#3B5323'
|
||||
ror: '#78AB46'
|
||||
run of river: '#78AB46'
|
||||
hydroelectricity: '#006400'
|
||||
# water
|
||||
hydro: '#298c81'
|
||||
hydro reservoir: '#298c81'
|
||||
ror: '#3dbfb0'
|
||||
run of river: '#3dbfb0'
|
||||
hydroelectricity: '#298c81'
|
||||
PHS: '#51dbcc'
|
||||
wave: '#a7d4cf'
|
||||
# solar
|
||||
solar: "#f9d002"
|
||||
solar PV: "#f9d002"
|
||||
solar thermal: coral
|
||||
solar rooftop: '#ffef60'
|
||||
OCGT: wheat
|
||||
OCGT marginal: sandybrown
|
||||
OCGT-heat: '#ee8340'
|
||||
gas boiler: '#ee8340'
|
||||
gas boilers: '#ee8340'
|
||||
gas boiler marginal: '#ee8340'
|
||||
gas-to-power/heat: '#ee8340'
|
||||
gas: brown
|
||||
natural gas: brown
|
||||
SMR: '#4F4F2F'
|
||||
oil: '#B5A642'
|
||||
oil boiler: '#B5A677'
|
||||
lines: k
|
||||
transmission lines: k
|
||||
H2: m
|
||||
H2 liquefaction: m
|
||||
hydrogen storage: m
|
||||
battery: slategray
|
||||
battery storage: slategray
|
||||
home battery: '#614700'
|
||||
home battery storage: '#614700'
|
||||
Nuclear: r
|
||||
Nuclear marginal: r
|
||||
nuclear: r
|
||||
uranium: r
|
||||
Coal: k
|
||||
coal: k
|
||||
Coal marginal: k
|
||||
Lignite: grey
|
||||
lignite: grey
|
||||
Lignite marginal: grey
|
||||
CCGT: '#ee8340'
|
||||
CCGT marginal: '#ee8340'
|
||||
heat pumps: '#76EE00'
|
||||
heat pump: '#76EE00'
|
||||
air heat pump: '#76EE00'
|
||||
ground heat pump: '#40AA00'
|
||||
power-to-heat: '#40AA00'
|
||||
resistive heater: pink
|
||||
Sabatier: '#FF1493'
|
||||
methanation: '#FF1493'
|
||||
power-to-gas: '#FF1493'
|
||||
power-to-liquid: '#FFAAE9'
|
||||
helmeth: '#7D0552'
|
||||
DAC: '#E74C3C'
|
||||
co2 stored: '#123456'
|
||||
CO2 sequestration: '#123456'
|
||||
CC: k
|
||||
co2: '#123456'
|
||||
co2 vent: '#654321'
|
||||
agriculture heat: '#D07A7A'
|
||||
agriculture machinery oil: '#1e1e1e'
|
||||
agriculture machinery oil emissions: '#111111'
|
||||
agriculture electricity: '#222222'
|
||||
solid biomass for industry co2 from atmosphere: '#654321'
|
||||
solid biomass for industry co2 to stored: '#654321'
|
||||
gas for industry co2 to atmosphere: '#654321'
|
||||
gas for industry co2 to stored: '#654321'
|
||||
Fischer-Tropsch: '#44DD33'
|
||||
kerosene for aviation: '#44BB11'
|
||||
naphtha for industry: '#44FF55'
|
||||
land transport oil: '#44DD33'
|
||||
water tanks: '#BBBBBB'
|
||||
hot water storage: '#BBBBBB'
|
||||
hot water charging: '#BBBBBB'
|
||||
hot water discharging: '#999999'
|
||||
CO2 pipeline: '#999999'
|
||||
CHP: r
|
||||
CHP heat: r
|
||||
CHP electric: r
|
||||
PHS: g
|
||||
Ambient: k
|
||||
Electric load: b
|
||||
Heat load: r
|
||||
heat: darkred
|
||||
rural heat: '#880000'
|
||||
central heat: '#b22222'
|
||||
decentral heat: '#800000'
|
||||
low-temperature heat for industry: '#991111'
|
||||
process heat: '#FF3333'
|
||||
heat demand: darkred
|
||||
electric demand: k
|
||||
Li ion: grey
|
||||
district heating: '#CC4E5C'
|
||||
retrofitting: purple
|
||||
building retrofitting: purple
|
||||
BEV charger: grey
|
||||
V2G: grey
|
||||
land transport EV: grey
|
||||
electricity: k
|
||||
gas for industry: '#333333'
|
||||
solid biomass for industry: '#555555'
|
||||
industry electricity: '#222222'
|
||||
industry new electricity: '#222222'
|
||||
solar thermal: '#ffbf2b'
|
||||
solar rooftop: '#ffea80'
|
||||
# gas
|
||||
OCGT: '#e0986c'
|
||||
OCGT marginal: '#e0986c'
|
||||
OCGT-heat: '#e0986c'
|
||||
gas boiler: '#db6a25'
|
||||
gas boilers: '#db6a25'
|
||||
gas boiler marginal: '#db6a25'
|
||||
gas: '#e05b09'
|
||||
natural gas: '#e05b09'
|
||||
CCGT: '#a85522'
|
||||
CCGT marginal: '#a85522'
|
||||
gas for industry co2 to atmosphere: '#692e0a'
|
||||
gas for industry co2 to stored: '#8a3400'
|
||||
gas for industry: '#853403'
|
||||
gas for industry CC: '#692e0a'
|
||||
gas pipeline: '#ebbca0'
|
||||
# oil
|
||||
oil: '#c9c9c9'
|
||||
oil boiler: '#adadad'
|
||||
agriculture machinery oil: '#949494'
|
||||
shipping oil: "#808080"
|
||||
land transport oil: '#afafaf'
|
||||
# nuclear
|
||||
Nuclear: '#ff8c00'
|
||||
Nuclear marginal: '#ff8c00'
|
||||
nuclear: '#ff8c00'
|
||||
uranium: '#ff8c00'
|
||||
# coal
|
||||
Coal: '#545454'
|
||||
coal: '#545454'
|
||||
Coal marginal: '#545454'
|
||||
solid: '#545454'
|
||||
Lignite: '#826837'
|
||||
lignite: '#826837'
|
||||
Lignite marginal: '#826837'
|
||||
# biomass
|
||||
biogas: '#e3d37d'
|
||||
biomass: '#baa741'
|
||||
solid biomass: '#baa741'
|
||||
solid biomass transport: '#baa741'
|
||||
solid biomass for industry: '#7a6d26'
|
||||
solid biomass for industry CC: '#47411c'
|
||||
solid biomass for industry co2 from atmosphere: '#736412'
|
||||
solid biomass for industry co2 to stored: '#47411c'
|
||||
# power transmission
|
||||
lines: '#6c9459'
|
||||
transmission lines: '#6c9459'
|
||||
electricity distribution grid: '#97ad8c'
|
||||
# electricity demand
|
||||
Electric load: '#110d63'
|
||||
electric demand: '#110d63'
|
||||
electricity: '#110d63'
|
||||
industry electricity: '#2d2a66'
|
||||
industry new electricity: '#2d2a66'
|
||||
agriculture electricity: '#494778'
|
||||
# battery + EVs
|
||||
battery: '#ace37f'
|
||||
battery storage: '#ace37f'
|
||||
home battery: '#80c944'
|
||||
home battery storage: '#80c944'
|
||||
BEV charger: '#baf238'
|
||||
V2G: '#e5ffa8'
|
||||
land transport EV: '#baf238'
|
||||
Li ion: '#baf238'
|
||||
# hot water storage
|
||||
water tanks: '#e69487'
|
||||
hot water storage: '#e69487'
|
||||
hot water charging: '#e69487'
|
||||
hot water discharging: '#e69487'
|
||||
# heat demand
|
||||
Heat load: '#cc1f1f'
|
||||
heat: '#cc1f1f'
|
||||
heat demand: '#cc1f1f'
|
||||
rural heat: '#ff5c5c'
|
||||
central heat: '#cc1f1f'
|
||||
decentral heat: '#750606'
|
||||
low-temperature heat for industry: '#8f2727'
|
||||
process heat: '#ff0000'
|
||||
agriculture heat: '#d9a5a5'
|
||||
# heat supply
|
||||
heat pumps: '#2fb537'
|
||||
heat pump: '#2fb537'
|
||||
air heat pump: '#36eb41'
|
||||
ground heat pump: '#2fb537'
|
||||
Ambient: '#98eb9d'
|
||||
CHP: '#8a5751'
|
||||
CHP CC: '#634643'
|
||||
CHP heat: '#8a5751'
|
||||
CHP electric: '#8a5751'
|
||||
district heating: '#e8beac'
|
||||
resistive heater: '#d8f9b8'
|
||||
retrofitting: '#8487e8'
|
||||
building retrofitting: '#8487e8'
|
||||
# hydrogen
|
||||
H2 for industry: "#f073da"
|
||||
H2 for shipping: "#ebaee0"
|
||||
H2: '#bf13a0'
|
||||
hydrogen: '#bf13a0'
|
||||
SMR: '#870c71'
|
||||
SMR CC: '#4f1745'
|
||||
H2 liquefaction: '#d647bd'
|
||||
hydrogen storage: '#bf13a0'
|
||||
H2 storage: '#bf13a0'
|
||||
land transport fuel cell: '#6b3161'
|
||||
H2 pipeline: '#f081dc'
|
||||
H2 Fuel Cell: '#c251ae'
|
||||
H2 Electrolysis: '#ff29d9'
|
||||
# syngas
|
||||
Sabatier: '#9850ad'
|
||||
methanation: '#c44ce6'
|
||||
methane: '#c44ce6'
|
||||
helmeth: '#e899ff'
|
||||
# synfuels
|
||||
Fischer-Tropsch: '#25c49a'
|
||||
liquid: '#25c49a'
|
||||
kerosene for aviation: '#a1ffe6'
|
||||
naphtha for industry: '#57ebc4'
|
||||
# co2
|
||||
CC: '#f29dae'
|
||||
CCS: '#f29dae'
|
||||
CO2 sequestration: '#f29dae'
|
||||
DAC: '#ff5270'
|
||||
co2 stored: '#f2385a'
|
||||
co2: '#f29dae'
|
||||
co2 vent: '#ffd4dc'
|
||||
CO2 pipeline: '#f5627f'
|
||||
# emissions
|
||||
process emissions CC: '#000000'
|
||||
process emissions: '#222222'
|
||||
process emissions to stored: '#444444'
|
||||
process emissions to atmosphere: '#888888'
|
||||
process emissions: '#222222'
|
||||
oil emissions: '#666666'
|
||||
land transport oil emissions: '#666666'
|
||||
land transport fuel cell: '#AAAAAA'
|
||||
biogas: '#800000'
|
||||
solid biomass: '#DAA520'
|
||||
today: '#D2691E'
|
||||
shipping: '#6495ED'
|
||||
shipping oil: "#6495ED"
|
||||
shipping oil emissions: "#6495ED"
|
||||
electricity distribution grid: '#333333'
|
||||
solid biomass transport: green
|
||||
H2 for industry: "#222222"
|
||||
H2 for shipping: "#6495ED"
|
||||
oil emissions: '#aaaaaa'
|
||||
shipping oil emissions: "#555555"
|
||||
land transport oil emissions: '#777777'
|
||||
agriculture machinery oil emissions: '#333333'
|
||||
# other
|
||||
shipping: '#03a2ff'
|
||||
power-to-heat: '#2fb537'
|
||||
power-to-gas: '#c44ce6'
|
||||
power-to-H2: '#ff29d9'
|
||||
power-to-liquid: '#25c49a'
|
||||
gas-to-power/heat: '#ee8340'
|
||||
waste: '#e3d37d'
|
||||
other: '#000000'
|
@ -34,11 +34,8 @@ def rename_techs(label):
|
||||
rename_if_contains_dict = {
|
||||
"water tanks": "hot water storage",
|
||||
"retrofitting": "building retrofitting",
|
||||
"H2 Electrolysis": "hydrogen storage",
|
||||
"H2 Fuel Cell": "hydrogen storage",
|
||||
"H2 pipeline": "hydrogen storage",
|
||||
"battery": "battery storage",
|
||||
"CC": "CC"
|
||||
# "CC": "CC"
|
||||
}
|
||||
|
||||
rename = {
|
||||
|
Loading…
Reference in New Issue
Block a user