version: 0.5.0 logging_level: INFO results_dir: results/ summary_dir: results costs_dir: ../technology-data/outputs/ run: your-run-name # use this to keep track of runs with different settings foresight: overnight # options are overnight, myopic, perfect (perfect is not yet implemented) # if you use myopic or perfect foresight, set the investment years in "planning_horizons" below scenario: simpl: # only relevant for PyPSA-Eur - '' lv: # allowed transmission line volume expansion, can be any float >= 1.0 (today) or "opt" - 1.0 - 1.5 clusters: # number of nodes in Europe, any integer between 37 (1 node per country-zone) and several hundred - 45 - 50 opts: # only relevant for PyPSA-Eur - '' sector_opts: # this is where the main scenario settings are - Co2L0-3H-T-H-B-I-solar+p3-dist1 # to really understand the options here, look in scripts/prepare_sector_network.py # Co2Lx specifies the CO2 target in x% of the 1990 values; default will give default (5%); # Co2L0p25 will give 25% CO2 emissions; Co2Lm0p05 will give 5% negative emissions # xH is the temporal resolution; 3H is 3-hourly, i.e. one snapshot every 3 hours # single letters are sectors: T for land transport, H for building heating, # B for biomass supply, I for industry, shipping and aviation # solar+c0.5 reduces the capital cost of solar to 50\% of reference value # solar+p3 multiplies the available installable potential by factor 3 # dist{n} includes distribution grids with investment cost of n times cost in data/costs.csv # for myopic/perfect foresight cb states the carbon budget in GtCO2 (cumulative # emissions throughout the transition path in the timeframe determined by the # planning_horizons), be:beta decay; ex:exponential decay # cb40ex0 distributes a carbon budget of 40 GtCO2 following an exponential # decay with initial growth rate 0 planning_horizons: # investment years for myopic and perfect; or costs year for overnight - 2030 # for example, set to [2020, 2030, 2040, 2050] for myopic foresight # CO2 budget as a fraction of 1990 emissions # this is over-ridden if CO2Lx is set in sector_opts # this is also over-ridden if cb is set in sector_opts co2_budget: 2020: 0.7011648746 2025: 0.5241935484 2030: 0.2970430108 2035: 0.1500896057 2040: 0.0712365591 2045: 0.0322580645 2050: 0 # snapshots are originally set in PyPSA-Eur/config.yaml but used again by PyPSA-Eur-Sec snapshots: # arguments to pd.date_range start: "2013-01-01" end: "2014-01-01" closed: left # end is not inclusive atlite: cutout: ../pypsa-eur/cutouts/europe-2013-era5.nc # this information is NOT used but needed as an argument for # pypsa-eur/scripts/add_electricity.py/load_costs in make_summary.py electricity: max_hours: battery: 6 H2: 168 # regulate what components with which carriers are kept from PyPSA-Eur; # some technologies are removed because they are implemented differently # or have different year-dependent costs in PyPSA-Eur-Sec pypsa_eur: Bus: - AC Link: - DC Generator: - onwind - offwind-ac - offwind-dc - solar - ror StorageUnit: - PHS - hydro Store: [] energy: energy_totals_year: 2011 base_emissions_year: 1990 eurostat_report_year: 2016 emissions: CO2 # "CO2" or "All greenhouse gases - (CO2 equivalent)" biomass: year: 2030 scenario: Med classes: solid biomass: - Primary agricultural residues - Forestry energy residue - Secondary forestry residues - Secondary Forestry residues sawdust - Forestry residues from landscape care biomass - Municipal waste not included: - Bioethanol sugar beet biomass - Rapeseeds for biodiesel - sunflower and soya for Biodiesel - Starchy crops biomass - Grassy crops biomass - Willow biomass - Poplar biomass potential - Roundwood fuelwood - Roundwood Chips & Pellets biogas: - Manure biomass potential - Sludge biomass solar_thermal: clearsky_model: simple # should be "simple" or "enhanced"? orientation: slope: 45. azimuth: 180. # only relevant for foresight = myopic or perfect existing_capacities: grouping_years: [1980, 1985, 1990, 1995, 2000, 2005, 2010, 2015, 2019] threshold_capacity: 10 conventional_carriers: - lignite - coal - oil - uranium sector: central: true central_fraction: 0.6 bev_dsm_restriction_value: 0.75 #Set to 0 for no restriction on BEV DSM bev_dsm_restriction_time: 7 #Time at which SOC of BEV has to be dsm_restriction_value transport_heating_deadband_upper: 20. transport_heating_deadband_lower: 15. ICE_lower_degree_factor: 0.375 #in per cent increase in fuel consumption per degree above deadband ICE_upper_degree_factor: 1.6 EV_lower_degree_factor: 0.98 EV_upper_degree_factor: 0.63 district_heating_loss: 0.15 bev_dsm: true #turns on EV battery bev_availability: 0.5 #How many cars do smart charging bev_energy: 0.05 #average battery size in MWh bev_charge_efficiency: 0.9 #BEV (dis-)charging efficiency bev_plug_to_wheel_efficiency: 0.2 #kWh/km from EPA https://www.fueleconomy.gov/feg/ for Tesla Model S bev_charge_rate: 0.011 #3-phase charger with 11 kW bev_avail_max: 0.95 bev_avail_mean: 0.8 v2g: true #allows feed-in to grid from EV battery #what is not EV or FCEV is oil-fuelled ICE land_transport_fuel_cell_share: # 1 means all FCEVs 2020: 0 2030: 0.05 2040: 0.1 2050: 0.15 land_transport_electric_share: # 1 means all EVs 2020: 0 2030: 0.25 2040: 0.6 2050: 0.85 transport_fuel_cell_efficiency: 0.5 transport_internal_combustion_efficiency: 0.3 shipping_average_efficiency: 0.4 #For conversion of fuel oil to propulsion in 2011 time_dep_hp_cop: true #time dependent heat pump coefficient of performance heat_pump_sink_T: 55. # Celsius, based on DTU / large area radiators; used in build_cop_profiles.py # conservatively high to cover hot water and space heating in poorly-insulated buildings reduce_space_heat_exogenously: true # reduces space heat demand by a given factor (applied before losses in DH) # this can represent e.g. building renovation, building demolition, or if # the factor is negative: increasing floor area, increased thermal comfort, population growth reduce_space_heat_exogenously_factor: # per unit reduction in space heat demand # the default factors are determined by the LTS scenario from http://tool.european-calculator.eu/app/buildings/building-types-area/?levers=1ddd4444421213bdbbbddd44444ffffff11f411111221111211l212221 2020: 0.10 # this results in a space heat demand reduction of 10% 2025: 0.09 # first heat demand increases compared to 2020 because of larger floor area per capita 2030: 0.09 2035: 0.11 2040: 0.16 2045: 0.21 2050: 0.29 retrofitting : # co-optimises building renovation to reduce space heat demand retro_endogen: false # co-optimise space heat savings cost_factor: 1.0 # weight costs for building renovation interest_rate: 0.04 # for investment in building components annualise_cost: true # annualise the investment costs tax_weighting: false # weight costs depending on taxes in countries construction_index: true # weight costs depending on labour/material costs per country tes: true tes_tau: # 180 day time constant for centralised, 3 day for decentralised decentral: 3 central: 180 boilers: true oil_boilers: false chp: true micro_chp: false solar_thermal: true solar_cf_correction: 0.788457 # = >>> 1/1.2683 marginal_cost_storage: 0. #1e-4 methanation: true helmeth: true dac: true co2_vent: true SMR: true co2_sequestration_potential: 200 #MtCO2/a sequestration potential for Europe co2_sequestration_cost: 20 #EUR/tCO2 for transport and sequestration of CO2 cc_fraction: 0.9 # default fraction of CO2 captured with post-combustion capture hydrogen_underground_storage: true use_fischer_tropsch_waste_heat: true use_fuel_cell_waste_heat: true electricity_distribution_grid: false electricity_distribution_grid_cost_factor: 1.0 #multiplies cost in data/costs.csv electricity_grid_connection: true # only applies to onshore wind and utility PV gas_network: true H2_retrofit: true # if set to True existing gas pipes can be retrofitted to H2 pipes H2_retrofit_capacity_per_CH4: 0.6 # ratio for H2 capacity per original CH4 capacity of retrofitted pipelines gas_distribution_grid: true gas_distribution_grid_cost_factor: 1.0 #multiplies cost in data/costs.csv conventional_generation: # generator : carrier OCGT: gas industry: St_primary_fraction: 0.3 # fraction of steel produced via primary route (DRI + EAF) versus secondary route (EAF); today fraction is 0.6 H2_DRI: 1.7 #H2 consumption in Direct Reduced Iron (DRI), MWh_H2,LHV/ton_Steel from 51kgH2/tSt in Vogl et al (2018) doi:10.1016/j.jclepro.2018.08.279 elec_DRI: 0.322 #electricity consumption in Direct Reduced Iron (DRI) shaft, MWh/tSt HYBRIT brochure https://ssabwebsitecdn.azureedge.net/-/media/hybrit/files/hybrit_brochure.pdf Al_primary_fraction: 0.2 # fraction of aluminium produced via the primary route versus scrap; today fraction is 0.4 MWh_CH4_per_tNH3_SMR: 10.8 # 2012's demand from https://ec.europa.eu/docsroom/documents/4165/attachments/1/translations/en/renditions/pdf MWh_elec_per_tNH3_SMR: 0.7 # same source, assuming 94-6% split methane-elec of total energy demand 11.5 MWh/tNH3 MWh_H2_per_tNH3_electrolysis: 6.5 # from https://doi.org/10.1016/j.joule.2018.04.017, around 0.197 tH2/tHN3 (>3/17 since some H2 lost and used for energy) MWh_elec_per_tNH3_electrolysis: 1.17 # from https://doi.org/10.1016/j.joule.2018.04.017 Table 13 (air separation and HB) NH3_process_emissions: 24.5 # in MtCO2/a from SMR for H2 production for NH3 from UNFCCC for 2015 for EU28 petrochemical_process_emissions: 25.5 # in MtCO2/a for petrochemical and other from UNFCCC for 2015 for EU28 HVC_primary_fraction: 1.0 #fraction of current non-ammonia basic chemicals produced via primary route hotmaps_locate_missing: false reference_year: 2015 costs: lifetime: 25 #default lifetime # From a Lion Hirth paper, also reflects average of Noothout et al 2016 discountrate: 0.07 # [EUR/USD] ECB: https://www.ecb.europa.eu/stats/exchange/eurofxref/html/eurofxref-graph-usd.en.html # noqa: E501 USD2013_to_EUR2013: 0.7532 # Marginal and capital costs can be overwritten # capital_cost: # onwind: 500 marginal_cost: solar: 0.01 onwind: 0.015 offwind: 0.015 hydro: 0. H2: 0. battery: 0. emission_prices: # only used with the option Ep (emission prices) co2: 0. lines: length_factor: 1.25 #to estimate offwind connection costs solving: #tmpdir: "path/to/tmp" options: formulation: kirchhoff clip_p_max_pu: 1.e-2 load_shedding: false noisy_costs: true skip_iterations: true track_iterations: false min_iterations: 4 max_iterations: 6 solver: name: gurobi threads: 4 method: 2 # barrier crossover: 0 BarConvTol: 1.e-6 Seed: 123 AggFill: 0 PreDual: 0 GURO_PAR_BARDENSETHRESH: 200 #FeasibilityTol: 1.e-6 #name: cplex #threads: 4 #lpmethod: 4 # barrier #solutiontype: 2 # non basic solution, ie no crossover #barrier_convergetol: 1.e-5 #feasopt_tolerance: 1.e-6 mem: 30000 #memory in MB; 20 GB enough for 50+B+I+H2; 100 GB for 181+B+I+H2 plotting: map: boundaries: [-11, 30, 34, 71] color_geomap: ocean: white land: whitesmoke costs_max: 1000 costs_threshold: 1 energy_max: 20000 energy_min: -20000 energy_threshold: 50 vre_techs: - onwind - offwind-ac - offwind-dc - solar - ror renewable_storage_techs: - PHS - hydro conv_techs: - OCGT - CCGT - Nuclear - Coal storage_techs: - hydro+PHS - battery - H2 load_carriers: - AC load AC_carriers: - AC line - AC transformer link_carriers: - DC line - Converter AC-DC heat_links: - heat pump - resistive heater - CHP heat - CHP electric - gas boiler - central heat pump - central resistive heater - central CHP heat - central CHP electric - central gas boiler heat_generators: - gas boiler - central gas boiler - solar thermal collector - central solar thermal collector tech_colors: onwind: "#235ebc" onshore wind: "#235ebc" offwind: "#6895dd" offshore wind: "#6895dd" offwind-ac: "#6895dd" offshore wind (AC): "#6895dd" offwind-dc: "#74c6f2" offshore wind (DC): "#74c6f2" wave: '#004444' hydro: '#3B5323' hydro reservoir: '#3B5323' ror: '#78AB46' run of river: '#78AB46' hydroelectricity: '#006400' solar: "#f9d002" solar PV: "#f9d002" solar thermal: coral solar rooftop: '#ffef60' OCGT: wheat OCGT marginal: sandybrown OCGT-heat: '#ee8340' gas boiler: '#ee8340' gas boilers: '#ee8340' gas boiler marginal: '#ee8340' gas-to-power/heat: '#ee8340' gas: brown Gas pipeline : brown natural gas: brown SMR: '#4F4F2F' SMR CC: '#6f6f42' oil: '#B5A642' oil boiler: '#B5A677' lines: k transmission lines: k H2: m hydrogen storage: m battery: slategray battery storage: slategray home battery: '#614700' home battery storage: '#614700' Nuclear: r Nuclear marginal: r nuclear: r uranium: r Coal: k coal: k Coal marginal: k Lignite: grey lignite: grey Lignite marginal: grey CCGT: '#ee8340' CCGT marginal: '#ee8340' heat pumps: '#76EE00' heat pump: '#76EE00' air heat pump: '#76EE00' ground heat pump: '#40AA00' power-to-heat: '#40AA00' resistive heater: pink Sabatier: '#FF1493' methanation: '#FF1493' power-to-gas: '#FF1493' power-to-liquid: '#FFAAE9' helmeth: '#7D0552' DAC: '#E74C3C' co2 stored: '#123456' CO2 sequestration: '#123456' CC: k co2: '#123456' co2 vent: '#654321' solid biomass for industry co2 from atmosphere: '#654321' solid biomass for industry co2 to stored: '#654321' gas for industry co2 to atmosphere: '#654321' gas for industry co2 to stored: '#654321' Fischer-Tropsch: '#44DD33' kerosene for aviation: '#44BB11' naphtha for industry: '#44FF55' land transport oil: '#44DD33' water tanks: '#BBBBBB' hot water storage: '#BBBBBB' hot water charging: '#BBBBBB' hot water discharging: '#999999' CHP: r CHP heat: r CHP electric: r PHS: g Ambient: k Electric load: b Heat load: r heat: darkred rural heat: '#880000' central heat: '#b22222' decentral heat: '#800000' low-temperature heat for industry: '#991111' process heat: '#FF3333' heat demand: darkred electric demand: k Li ion: grey district heating: '#CC4E5C' retrofitting: purple building retrofitting: purple BEV charger: grey V2G: grey land transport EV: grey electricity: k gas for industry: '#333333' gas for industry CC: '#404040' solid biomass for industry: '#555555' solid biomass for industry CC: '#555555' industry electricity: '#222222' industry new electricity: '#222222' process emissions to stored: '#444444' process emissions to atmosphere: '#888888' process emissions: '#222222' process emissions CC: '#484848' oil emissions: '#666666' land transport oil emissions: '#666666' land transport fuel cell: '#AAAAAA' biogas: '#800000' solid biomass: '#DAA520' today: '#D2691E' shipping: '#6495ED' electricity distribution grid: '#333333'