diff --git a/config_float.yaml b/config_float.yaml deleted file mode 100755 index d99764d4..00000000 --- a/config_float.yaml +++ /dev/null @@ -1,333 +0,0 @@ -# SPDX-FileCopyrightText: : 2017-2020 The PyPSA-Eur Authors -# -# SPDX-License-Identifier: CC0-1.0 - -version: 0.4.0 -tutorial: false - -logging: - level: INFO - format: '%(levelname)s:%(name)s:%(message)s' - -summary_dir: results - -scenario: - simpl: [''] - ll: ['copt'] - clusters: [100] - opts: [Co2L-24H] - -countries: ['BE','DE', 'DK', 'GB', 'NL', 'NO'] - -clustering: - simplify: - to_substations: false # network is simplified to nodes with positive or negative power injection (i.e. substations or offwind connections) - -snapshots: - start: "2013-01-01" - end: "2014-01-01" - closed: 'left' # end is not inclusive - -enable: - prepare_links_p_nom: false - retrieve_databundle: true - build_cutout: false - retrieve_cutout: false - build_natura_raster: false - retrieve_natura_raster: true - custom_busmap: false - split_offshore_regions: true #splits big offshore regions into smaller regions - build_ship_raster: true - retrieve_ship_raster: true - -electricity: - voltages: [220., 300., 380.] - co2limit: 7.75e+7 # 0.05 * 3.1e9*0.5 - co2base: 1.487e+9 - agg_p_nom_limits: data/agg_p_nom_minmax.csv - - extendable_carriers: - Generator: [] - StorageUnit: [] # battery, H2 - Store: [battery, H2] - Link: [] - - max_hours: - battery: 6 - H2: 168 - - powerplants_filter: false # use pandas query strings here, e.g. Country not in ['Germany'] - custom_powerplants: false # use pandas query strings here, e.g. Country in ['Germany'] - conventional_carriers: [nuclear, oil, OCGT, CCGT, coal, lignite, geothermal, biomass] - renewable_capacities_from_OPSD: [] # onwind, offwind, solar - - # estimate_renewable_capacities_from_capacity_stats: - # # Wind is the Fueltype in ppm.data.Capacity_stats, onwind, offwind-{ac,dc} the carrier in PyPSA-Eur - # Wind: [onwind, offwind-ac, offwind-dc] - # Solar: [solar] - -atlite: - nprocesses: 1 - show_progress: false - cutouts: - # use 'base' to determine geographical bounds and time span from config - # base: - # module: era5 - europe-2013-era5: - module: era5 # in priority order - dx: 0.3 - dy: 0.3 - time: ['2013', '2013'] - - -renewable: - onwind: - cutout: europe-2013-era5 - resource: - method: wind - turbine: Vestas_V112_3MW - capacity_per_sqkm: 3 # ScholzPhd Tab 4.3.1: 10MW/km^2 - # correction_factor: 0.93 - corine: - # Scholz, Y. (2012). Renewable energy based electricity supply at low costs: - # development of the REMix model and application for Europe. ( p.42 / p.28) - grid_codes: [12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, - 24, 25, 26, 27, 28, 29, 31, 32] - distance: 1000 - distance_grid_codes: [1, 2, 3, 4, 5, 6] - natura: true - potential: simple # or conservative - clip_p_max_pu: 1.e-2 - offwind-ac: - cutout: europe-2013-era5 - resource: - method: wind - turbine: NREL_ReferenceTurbine_2020ATB_12MW_offshore - capacity_per_sqkm: 2 - correction_factor: 0.8855 - # proxy for wake losses - # from 10.1016/j.energy.2018.08.153 - # until done more rigorously in #153 - #corine: [44, 255] - natura: true - max_depth: 60 - max_shore_distance: 30000 - potential: simple # or conservative - clip_p_max_pu: 1.e-2 - calculate_topology_cost: true - offwind-dc: - cutout: europe-2013-era5 - resource: - method: wind - turbine: NREL_ReferenceTurbine_2020ATB_12MW_offshore - capacity_per_sqkm: 2 - correction_factor: 0.8855 - # proxy for wake losses - # from 10.1016/j.energy.2018.08.153 - # until done more rigorously in #153 - #corine: [44, 255] - natura: true - max_depth: 60 - min_shore_distance: 30000 - potential: simple # or conservative - clip_p_max_pu: 1.e-2 - calculate_topology_cost: true - offwind-float: - cutout: europe-2013-era5 - resource: - method: wind - turbine: NREL_ReferenceTurbine_5MW_offshore - # ScholzPhd Tab 4.3.1: 10MW/km^2 - capacity_per_sqkm: 2 - correction_factor: 0.8855 - # proxy for wake losses - # from 10.1016/j.energy.2018.08.153 - # until done more rigorously in #153 - #corine: [44, 255] - natura: true - min_depth: 60 - potential: simple # or conservative - clip_p_max_pu: 1.e-2 - solar: - cutout: europe-2013-era5 - resource: - method: pv - panel: CSi - orientation: - slope: 35. - azimuth: 180. - capacity_per_sqkm: 1.7 # ScholzPhd Tab 4.3.1: 170 MW/km^2 - # Correction factor determined by comparing uncorrected area-weighted full-load hours to those - # published in Supplementary Data to - # Pietzcker, Robert Carl, et al. "Using the sun to decarbonize the power - # sector: The economic potential of photovoltaics and concentrating solar - # power." Applied Energy 135 (2014): 704-720. - # This correction factor of 0.854337 may be in order if using reanalysis data. - # for discussion refer to https://github.com/PyPSA/pypsa-eur/pull/304 - # correction_factor: 0.854337 - corine: [1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, - 14, 15, 16, 17, 18, 19, 20, 26, 31, 32] - natura: true - potential: simple # or conservative - clip_p_max_pu: 1.e-2 - hydro: - cutout: europe-2013-era5 - carriers: [ror, PHS, hydro] - PHS_max_hours: 6 - hydro_max_hours: "energy_capacity_totals_by_country" # one of energy_capacity_totals_by_country, estimate_by_large_installations or a float - clip_min_inflow: 1.0 - -lines: - types: - 220.: "Al/St 240/40 2-bundle 220.0" - 300.: "Al/St 240/40 3-bundle 300.0" - 380.: "Al/St 240/40 4-bundle 380.0" - s_max_pu: 0.7 - s_nom_max: .inf - length_factor: 1.25 - under_construction: 'zero' # 'zero': set capacity to zero, 'remove': remove, 'keep': with full capacity - -links: - p_max_pu: 1.0 - p_nom_max: .inf - include_tyndp: true - under_construction: 'zero' # 'zero': set capacity to zero, 'remove': remove, 'keep': with full capacity - -transformers: - x: 0.1 - s_nom: 2000. - type: '' - -load: - power_statistics: True # only for files from <2019; set false in order to get ENTSOE transparency data - interpolate_limit: 3 # data gaps up until this size are interpolated linearly - time_shift_for_large_gaps: 1w # data gaps up until this size are copied by copying from - manual_adjustments: true # false - scaling_factor: 1.0 - -costs: - year: 2030 - discountrate: 0.07 # From a Lion Hirth paper, also reflects average of Noothout et al 2016 - USD2013_to_EUR2013: 0.7532 # [EUR/USD] ECB: https://www.ecb.europa.eu/stats/exchange/eurofxref/html/eurofxref-graph-usd.en.html - marginal_cost: # EUR/MWh - solar: 0.01 - onwind: 0.015 - offwind-ac: 0.015 - offwind-dc: 0.015 - hydro: 0. - H2: 0. - electrolysis: 0. - fuel cell: 0. - battery: 0. - battery inverter: 0. - emission_prices: # in currency per tonne emission, only used with the option Ep - co2: 0. - -solving: - options: - formulation: kirchhoff - load_shedding: false - noisy_costs: true - min_iterations: 4 - max_iterations: 6 - clip_p_max_pu: 0.01 - skip_iterations: false - track_iterations: false - #nhours: 10 - solver: - name: gurobi - threads: 4 - method: 2 # barrier - crossover: 0 - BarConvTol: 1.e-5 - FeasibilityTol: 1.e-6 - AggFill: 0 - PreDual: 0 - GURO_PAR_BARDENSETHRESH: 200 - # solver: - # name: cplex - # threads: 4 - # lpmethod: 4 # barrier - # solutiontype: 2 # non basic solution, ie no crossover - # barrier.convergetol: 1.e-5 - # feasopt.tolerance: 1.e-6 - -plotting: - map: - figsize: [7, 7] - boundaries: [-10.2, 29, 35, 72] - p_nom: - bus_size_factor: 5.e+4 - linewidth_factor: 3.e+3 - - costs_max: 800 - costs_threshold: 1 - - energy_max: 15000. - energy_min: -10000. - energy_threshold: 50. - - vre_techs: ["onwind", "offwind-ac", "offwind-dc", "solar", "ror"] - conv_techs: ["OCGT", "CCGT", "Nuclear", "Coal"] - storage_techs: ["hydro+PHS", "battery", "H2"] - load_carriers: ["AC load"] - AC_carriers: ["AC line", "AC transformer"] - link_carriers: ["DC line", "Converter AC-DC"] - tech_colors: - "onwind" : "#235ebc" - "onshore wind" : "#235ebc" - 'offwind' : "#6895dd" - 'offwind-ac' : "#6895dd" - 'offshore wind' : "#6895dd" - 'offshore wind ac' : "#6895dd" - 'offwind-dc' : "#74c6f2" - 'offshore wind dc' : "#74c6f2" - "hydro" : "#08ad97" - "hydro+PHS" : "#08ad97" - "PHS" : "#08ad97" - "hydro reservoir" : "#08ad97" - 'hydroelectricity' : '#08ad97' - "ror" : "#4adbc8" - "run of river" : "#4adbc8" - 'solar' : "#f9d002" - 'solar PV' : "#f9d002" - 'solar thermal' : '#ffef60' - 'biomass' : '#0c6013' - 'solid biomass' : '#06540d' - 'biogas' : '#23932d' - 'waste' : '#68896b' - 'geothermal' : '#ba91b1' - "OCGT" : "#d35050" - "gas" : "#d35050" - "natural gas" : "#d35050" - "CCGT" : "#b20101" - "nuclear" : "#ff9000" - "coal" : "#707070" - "lignite" : "#9e5a01" - "oil" : "#262626" - "H2" : "#ea048a" - "hydrogen storage" : "#ea048a" - "battery" : "#b8ea04" - "Electric load" : "#f9d002" - "electricity" : "#f9d002" - "lines" : "#70af1d" - "transmission lines" : "#70af1d" - "AC-AC" : "#70af1d" - "AC line" : "#70af1d" - "links" : "#8a1caf" - "HVDC links" : "#8a1caf" - "DC-DC" : "#8a1caf" - "DC link" : "#8a1caf" - nice_names: - OCGT: "Open-Cycle Gas" - CCGT: "Combined-Cycle Gas" - offwind-ac: "Offshore Wind (AC)" - offwind-dc: "Offshore Wind (DC)" - onwind: "Onshore Wind" - solar: "Solar" - PHS: "Pumped Hydro Storage" - hydro: "Reservoir & Dam" - battery: "Battery Storage" - H2: "Hydrogen Storage" - lines: "Transmission Lines" - ror: "Run of River"